Manual measurement of SD-OCT images of hyperreflective retinal layers in acute retinal vessel occlusion is reliable, repeatable and reproducible

To investigate the repeatability and reproducibility of manual measurements of the reflectivity of retinal layers in healthy eyes and in eyes with acute retinal vessel occlusion via spectral-domain optical coherence tomography (SD-OCT). To reflect the full spectrum of different reflectivities seen in OCT images, for each of the following conditions, exactly one patient with a healthy and an affected eye was selected: non-ischemic central retinal vein occlusion (CRVO), ischemic CRVO, incomplete, subtotal and total central retinal artery occlusion (CRAO). For all the patients, OCT images of the healthy and affected eyes were used. Each image was presented 10 times in a randomly changing sequence to all examiners (one experienced, two nonexperienced). The obtained values were analyzed via two statistical methods: Gage Repeatability & Reproducibility (Gage R&R, a measurement system analysis) and Lin's concordance correlation coefficient (Lin's CCC). The total gage R&R values were as follows: vitreous body (VB) 1.11%, innermost retinal layer (IMRL) 0.94%, middle retinal layer (MRL) 4.94%, inner retinal layer (IRL) 2.56% and outer retinal layer (ORL) 3.77%. The repeatability values were 0.79, 0.62, 2.80, 1.42 And 2.60, respectively. The reproducibility values were 0.32, 0.33, 2.41, 1.14 and 1.16, respectively. Our previously described method of manual measurement of SD-OCT images of retinal layers determining the level of reflectivity (and hence ischemia) in the retina without any invasive examination is reliable, repeatable, reproducible and feasible for clinical use. Registry: ClinicalTrials.gov, Protocol ID: EK 417,102,016, TRN: NCT03061526, Registration date: 19 February 2017.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-03
DOI
https://doi.org/10.1038/s41598-025-20086-7
Citations
1
Primary Topic
Retinal and Optic Conditions
Type
article
Field-Weighted Citation Impact
1.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Manual measurement of SD-OCT images of hyperreflective retinal layers in acute retinal vessel occlusion is reliable, repeatable and reproducible

Matthias Kühn, Egbert Matthé, Dierk Wittig, Dirk Sandner et al.
1 citations
Scientific Reports
Retinal and Optic Conditions
1.71
article

Manual measurement of SD-OCT images of hyperreflective retinal layers in acute retinal vessel occlusion is reliable, repeatable and reproducible

Matthias Kühn, Egbert Matthé, Dierk Wittig, Dirk Sandner, Peggy Eulitz, Olga Furashova, Katharina Schoen
article en
1 citations

Abstract

To investigate the repeatability and reproducibility of manual measurements of the reflectivity of retinal layers in healthy eyes and in eyes with acute retinal vessel occlusion via spectral-domain optical coherence tomography (SD-OCT). To reflect the full spectrum of different reflectivities seen in OCT images, for each of the following conditions, exactly one patient with a healthy and an affected eye was selected: non-ischemic central retinal vein occlusion (CRVO), ischemic CRVO, incomplete, subtotal and total central retinal artery occlusion (CRAO). For all the patients, OCT images of the healthy and affected eyes were used. Each image was presented 10 times in a randomly changing sequence to all examiners (one experienced, two nonexperienced). The obtained values were analyzed via two statistical methods: Gage Repeatability & Reproducibility (Gage R&R, a measurement system analysis) and Lin's concordance correlation coefficient (Lin's CCC). The total gage R&R values were as follows: vitreous body (VB) 1.11%, innermost retinal layer (IMRL) 0.94%, middle retinal layer (MRL) 4.94%, inner retinal layer (IRL) 2.56% and outer retinal layer (ORL) 3.77%. The repeatability values were 0.79, 0.62, 2.80, 1.42 And 2.60, respectively. The reproducibility values were 0.32, 0.33, 2.41, 1.14 and 1.16, respectively. Our previously described method of manual measurement of SD-OCT images of retinal layers determining the level of reflectivity (and hence ischemia) in the retina without any invasive examination is reliable, repeatable, reproducible and feasible for clinical use. Registry: ClinicalTrials.gov, Protocol ID: EK 417,102,016, TRN: NCT03061526, Registration date: 19 February 2017.

Scientific ReportsVol. 15(1)
Bayreuth Medical Center (DE), Schön Klinik Neustadt (DE), University Hospital Carl Gustav Carus (DE), Klinikum Chemnitz (DE), Klinik und Poliklinik für Augenheilkunde am Universitätsklinikum Carl Gustav Carus (DE), Baidu (China) (CN)
Openalex Percentile: Top 13%
Retinal and Optic Conditions
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.