Accuracy of Patient Setup Using Surface Guided Radiotherapy (SGRT) for Abdominal Malignancies

This study aimed to evaluate the placement accuracy and reproducibility of Surface Guided Radiotherapy (SGRT) compared with the conventional tattoo/laser method in patients undergoing radiotherapy for abdominal malignancies. A retrospective analysis was conducted on 43 patients treated with either SGRT (Group A) or the tattoo/laser technique (Group B). Patients in both groups underwent CBCT to quantify the positioning shifts in the vertical (<i>Svrt</i>), lateral (<i>Slat</i>) and longitudinal (<i>Slng</i>) axes, as well as the total shift. Statistical indicators including median, interquartile range (IQR), and range were calculated, and Mann-Whitney U tests were performed due to non-normal data distribution. Median values in all axes were same between groups: <i>Svrt</i> = 0.4 cm, <i>Slat</i> = 0.2 cm, <i>Slng</i> = 0.4 cm. Group A showed a higher total median shift equal to 0.8 cm versus 0.7 cm of Group B. However, IQRs were smaller in the Group B for all directions and total shift, indicating greater method consistency. Statistically significant differences (<i>p</i> < 0.05) were observed in all axes, except the vertical. These findings suggest that, while SGRT achieves comparable median alignment, its use in a highly variable anatomical region such as the abdomen may be associated with greater setup variability.

Authors

Institutions

Publication Details

Journal
Methods and Protocols
Published
2025-10-03
DOI
https://doi.org/10.3390/mps8050119
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Patient Setup Using Surface Guided Radiotherapy (SGRT) for Abdominal Malignancies

Stefanos Kachris, Varvara Sotiropoulou, Michalis Mazonakis
1 citations
Methods and Protocols
Advanced Radiotherapy Techniques
1.88
article

Accuracy of Patient Setup Using Surface Guided Radiotherapy (SGRT) for Abdominal Malignancies

Stefanos Kachris, Varvara Sotiropoulou, Michalis Mazonakis
article en
1 citations

Abstract

This study aimed to evaluate the placement accuracy and reproducibility of Surface Guided Radiotherapy (SGRT) compared with the conventional tattoo/laser method in patients undergoing radiotherapy for abdominal malignancies. A retrospective analysis was conducted on 43 patients treated with either SGRT (Group A) or the tattoo/laser technique (Group B). Patients in both groups underwent CBCT to quantify the positioning shifts in the vertical (<i>Svrt</i>), lateral (<i>Slat</i>) and longitudinal (<i>Slng</i>) axes, as well as the total shift. Statistical indicators including median, interquartile range (IQR), and range were calculated, and Mann-Whitney U tests were performed due to non-normal data distribution. Median values in all axes were same between groups: <i>Svrt</i> = 0.4 cm, <i>Slat</i> = 0.2 cm, <i>Slng</i> = 0.4 cm. Group A showed a higher total median shift equal to 0.8 cm versus 0.7 cm of Group B. However, IQRs were smaller in the Group B for all directions and total shift, indicating greater method consistency. Statistically significant differences (<i>p</i> < 0.05) were observed in all axes, except the vertical. These findings suggest that, while SGRT achieves comparable median alignment, its use in a highly variable anatomical region such as the abdomen may be associated with greater setup variability.

Methods and ProtocolsVol. 8(5)
University of Crete (GR), University Hospital of Heraklion (GR)
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of Patient Setup Using Surface Guided Radiotherapy (SGRT) for Abdominal Malignancies — Stefanos Kachris, Varvara Sotiropoulou, et al. · Methods and Protocols (2025) | TGRS Research Map | TGRS