Evaluation of patient-specific quality assurance in spot-scanning proton therapy using 2D ionisation chamber array

Abstract Purpose: This study aimed to report the outcomes of patient-specific quality assurance (QA) in spot-scanning proton therapy using a two-dimensional ionisation chamber array and investigate the relationship between gamma passing rate and plan parameters. Materials and methods: Patient-specific QA was performed and evaluated by gamma analysis using a 3% dose difference and 2-mm distance-to-agreement with 172 treatment plans in the head and neck, breast, chest, abdominal and pelvic regions. The outcomes of patient-specific quality assurance regarding the gamma passing rate of the treatment sites, monitor unit (MU) per spot, measurement depth, range shifter, number of spots, energy layer and target volume were analysed. Results: No significant difference ( p = 0·10 ) in the gamma passing rates between the treatment sites. The gamma passing rate was >98% in all the regions. The overall result of patient-specific QA with the gamma evaluation was 99·1 ± 1·6%. For the MU per spot, range shifter and measurement depth, the gamma passing rate was >98%. The gamma passing rate of the number of spots, energy layer and target volume was >97%. Conclusion: Patient-specific QA measurements showed that the gamma passing rate was >98% and was independent of the treatment site, MU per spot, range shifter, number of spots, energy layer and target volume but depend on measurement depth ( p < 0·05) . A gamma index of 3%, 2 mm forms reasonable criteria for patient-specific QA in spot-scanning proton therapy.

Authors

Institutions

Publication Details

Journal
Journal of Radiotherapy in Practice
Published
2025-01-01
DOI
https://doi.org/10.1017/s1460396925000172
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of patient-specific quality assurance in spot-scanning proton therapy using 2D ionisation chamber array

Sornjarod Oonsiri, Nichakan Chatchumnan, Mananchaya Vimolnoch, Puntiwa Oonsiri et al.
1 citations
Journal of Radiotherapy in Practice
Advanced Radiotherapy Techniques
1.88
article

Evaluation of patient-specific quality assurance in spot-scanning proton therapy using 2D ionisation chamber array

Sornjarod Oonsiri, Nichakan Chatchumnan, Mananchaya Vimolnoch, Puntiwa Oonsiri, Sakda Kingkaew, Nuttida Rawiwan
article en
1 citations

Abstract

Abstract Purpose: This study aimed to report the outcomes of patient-specific quality assurance (QA) in spot-scanning proton therapy using a two-dimensional ionisation chamber array and investigate the relationship between gamma passing rate and plan parameters. Materials and methods: Patient-specific QA was performed and evaluated by gamma analysis using a 3% dose difference and 2-mm distance-to-agreement with 172 treatment plans in the head and neck, breast, chest, abdominal and pelvic regions. The outcomes of patient-specific quality assurance regarding the gamma passing rate of the treatment sites, monitor unit (MU) per spot, measurement depth, range shifter, number of spots, energy layer and target volume were analysed. Results: No significant difference ( p = 0·10 ) in the gamma passing rates between the treatment sites. The gamma passing rate was >98% in all the regions. The overall result of patient-specific QA with the gamma evaluation was 99·1 ± 1·6%. For the MU per spot, range shifter and measurement depth, the gamma passing rate was >98%. The gamma passing rate of the number of spots, energy layer and target volume was >97%. Conclusion: Patient-specific QA measurements showed that the gamma passing rate was >98% and was independent of the treatment site, MU per spot, range shifter, number of spots, energy layer and target volume but depend on measurement depth ( p < 0·05) . A gamma index of 3%, 2 mm forms reasonable criteria for patient-specific QA in spot-scanning proton therapy.

Journal of Radiotherapy in PracticeVol. 24
Chulalongkorn University (TH), King Chulalongkorn Memorial Hospital (TH)
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.