Polarization-Induced Multimode Terahertz Metamaterial for High-Sensitivity and Label-free Drug Monitoring

Therapeutic drug monitoring (TDM) requires analytical technologies with high sensitivity, accuracy, and efficiency. Terahertz (THz) metamaterials offer strong THz electromagnetic field-analyte interactions and enable label-free detection with minimal sample consumption. However, most conventional designs rely on a single mode resonance (either single peak or multiple peaks), which limits modal diversity and thus causes in peak instability, sensitivity fluctuations, and a lack of real-time error validation. In this work, we propose a polarization-induced multimode THz metamaterial sensor that enable highly sensitive and accurate detection for TDM applications. By selectively exciting orthogonal electromagnetic modes under <i>x</i>- and <i>y</i>-polarized THz waves, the sensor generates multiple decoupled resonances with complementary field localization and well-separated spectral peaks. Each resonance mode couples to a distinct molecular vibration of the analyte, enabling multiplexed molecular identification and quantification. Clopidogrel sulfate, a widely used antithrombotic drug, was selected as a representative analyte validate the sensor performance. The resonance peaks of the polarization-induced multimode sensor were precisely adjusted to match the drug's characteristic absorption bands. An ultralow limit of detection (LOD) of 3.0 pg/μL was achieved, representing a 1000-fold sensitivity improvement over conventional HPLC methods, while maintaining over 95% consistency. When applied to human blood samples, the sensor achieved 93.7% accuracy and a 5 min detection time per sample (postpretreatment), demonstrating its potential for rapid TDM. Overall, the polarization-induced multimode THz metamaterial offers a highly sensitive, accurate, and efficient platform for trace-level drug detection, providing a promising solution for personalized medication management.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-03
DOI
https://doi.org/10.1021/acs.analchem.5c04376
Citations
3
Primary Topic
Metamaterials and Metasurfaces Applications
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polarization-Induced Multimode Terahertz Metamaterial for High-Sensitivity and Label-free Drug Monitoring

Sungjoon Lim, Jinjing Zhang, Wencan Liu, Yiming Zhu et al.
3 citations
Analytical Chemistry
Metamaterials and Metasurfaces Applications
1.28
article

Polarization-Induced Multimode Terahertz Metamaterial for High-Sensitivity and Label-free Drug Monitoring

Sungjoon Lim, Jinjing Zhang, Wencan Liu, Yiming Zhu, Jihong Zhu, Bingwei Liu, Xu Wu, Geunchang Choi, Yan Peng, Jiawei Li
article en
3 citations

Abstract

Therapeutic drug monitoring (TDM) requires analytical technologies with high sensitivity, accuracy, and efficiency. Terahertz (THz) metamaterials offer strong THz electromagnetic field-analyte interactions and enable label-free detection with minimal sample consumption. However, most conventional designs rely on a single mode resonance (either single peak or multiple peaks), which limits modal diversity and thus causes in peak instability, sensitivity fluctuations, and a lack of real-time error validation. In this work, we propose a polarization-induced multimode THz metamaterial sensor that enable highly sensitive and accurate detection for TDM applications. By selectively exciting orthogonal electromagnetic modes under <i>x</i>- and <i>y</i>-polarized THz waves, the sensor generates multiple decoupled resonances with complementary field localization and well-separated spectral peaks. Each resonance mode couples to a distinct molecular vibration of the analyte, enabling multiplexed molecular identification and quantification. Clopidogrel sulfate, a widely used antithrombotic drug, was selected as a representative analyte validate the sensor performance. The resonance peaks of the polarization-induced multimode sensor were precisely adjusted to match the drug's characteristic absorption bands. An ultralow limit of detection (LOD) of 3.0 pg/μL was achieved, representing a 1000-fold sensitivity improvement over conventional HPLC methods, while maintaining over 95% consistency. When applied to human blood samples, the sensor achieved 93.7% accuracy and a 5 min detection time per sample (postpretreatment), demonstrating its potential for rapid TDM. Overall, the polarization-induced multimode THz metamaterial offers a highly sensitive, accurate, and efficient platform for trace-level drug detection, providing a promising solution for personalized medication management.

Analytical ChemistryVol. 97(40)
Tongji University (CN), University of Shanghai for Science and Technology (CN), Hainan Normal University (CN), Second Military Medical University (CN), Shenzhen Terahertz Technology Innovation Research Institute (CN), Changhai Hospital (CN), Chung-Ang University (KR)
Openalex Percentile: Top 18%
Metamaterials and Metasurfaces Applications
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.