Infrared thermal mapping of osteotomy: influence of drill diameter and implant system
The study found significant variations in temperature increase based on the implant system and drill diameter. Baseline temperature, pilot drill, and second drill temperatures were significant predictors of the third final drill temperature, while the implant system itself was not a significant factor.
Authors
- Iván Calderón (ORCID: https://orcid.org/0009-0008-4572-5669)
- Franco Mauricio (ORCID: https://orcid.org/0000-0003-3658-0302)
- Daniel Alvítez-Temoche (ORCID: https://orcid.org/0000-0002-3337-4098)
- Adrían V. Hernández (ORCID: https://orcid.org/0000-0002-9999-4003)
- Frank Mayta‐Tovalino (ORCID: https://orcid.org/0000-0002-3280-0024)
- Fran Espinoza‐Carhuancho (ORCID: https://orcid.org/0009-0000-4692-942X)
- Mabel Huaman-De la Cruz
- Gabriel Barriga-Yauri (ORCID: https://orcid.org/0009-0003-2157-5444)
- Berly Delgado-Cumpa
Institutions
- Federico Villarreal National University (PE)
- University of Connecticut (US)
- National University of San Marcos (PE)
- Universidad Científica del Sur (PE)
- Universidad San Ignacio de Loyola (PE)
Publication Details
- Journal
- Frontiers in Oral Health
- Published
- 2025-10-03
- DOI
- https://doi.org/10.3389/froh.2025.1660374
- Citations
- 1
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 1.79