Dosimetric Analysis of Fast-Forward Breast Radiotherapy Using 3D-Conformal Radiotherapy (3D-CRT) With Deep Inspiratory Breath Hold (DIBH)

Introduction and aim Fast-forward radiotherapy (26 Gy in five fractions) has gained widespread acceptance for early-stage breast cancer due to its convenience and efficacy. However, in left-sided cases, there is a risk of radiation-induced cardiac and pulmonary toxicity due to the proximity of the heart and lungs. The voluntary deep inspiration breath-hold (vDIBH) technique increases thoracic volume and heart-chest wall distance, offering a non-invasive method to minimize organ-at-risk exposure. This study aimed to evaluate the dosimetric benefits of 3D-conformal radiotherapy (3D-CRT) combined with voluntary deep inspiration breath hold (vDIBH) in minimizing radiation dose to the heart and lungs during ultra-hypofractionated whole-breast irradiation in patients with left-sided breast cancer. Materials and methods We retrospectively analyzed 28 patients with left-sided breast cancer treated with 3D-CRT under vDIBH, receiving 26 Gy in five fractions. Target volumes and organs at risk (OARs) were contoured on vDIBH CT scans. Treatment planning was performed using tangential fields. Dosimetric parameters for the planning target volume (PTV), heart, ipsilateral lung, contralateral breast, and spinal cord were evaluated using dose-volume histograms (DVHs). Reproducibility of vDIBH was ensured by using in-room lasers, skin tattoos, and cine-mode imaging for intrafraction verification. Results Mean PTV V95% was 97.74±1.74%, with a mean dose of 26.61±0.25 Gy. The mean heart dose was 3.97±0.82 Gy, with V25% at 13.28±3.44%. Ipsilateral lung mean dose (D<sub>mean</sub>) was 8.26±0.76 Gy, and V30% was 32.81±2.85%. Contralateral breast V5% was 5.19±7.06%. The spinal cord received a negligible dose (maximum dose {D<sub>max</sub>}​​​​ 0.49±0.12 Gy). All patients tolerated vDIBH well, with no delays or treatment interruptions. Conclusion 3D-CRT with vDIBH offers a practical, reproducible, and cost-effective approach for delivering hypofractionated radiotherapy in left-sided breast cancer. It ensures excellent target coverage while significantly reducing radiation dose to critical structures, such as the heart and lungs, supporting its use as a standard practice even in resource-constrained settings.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-02
DOI
https://doi.org/10.7759/cureus.93746
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Analysis of Fast-Forward Breast Radiotherapy Using 3D-Conformal Radiotherapy (3D-CRT) With Deep Inspiratory Breath Hold (DIBH)

Aaditya Prakash, Subhankar Show, M Ajithkumar
Cureus
Advanced Radiotherapy Techniques
article

Dosimetric Analysis of Fast-Forward Breast Radiotherapy Using 3D-Conformal Radiotherapy (3D-CRT) With Deep Inspiratory Breath Hold (DIBH)

Aaditya Prakash, Subhankar Show, M Ajithkumar
article en

Abstract

Introduction and aim Fast-forward radiotherapy (26 Gy in five fractions) has gained widespread acceptance for early-stage breast cancer due to its convenience and efficacy. However, in left-sided cases, there is a risk of radiation-induced cardiac and pulmonary toxicity due to the proximity of the heart and lungs. The voluntary deep inspiration breath-hold (vDIBH) technique increases thoracic volume and heart-chest wall distance, offering a non-invasive method to minimize organ-at-risk exposure. This study aimed to evaluate the dosimetric benefits of 3D-conformal radiotherapy (3D-CRT) combined with voluntary deep inspiration breath hold (vDIBH) in minimizing radiation dose to the heart and lungs during ultra-hypofractionated whole-breast irradiation in patients with left-sided breast cancer. Materials and methods We retrospectively analyzed 28 patients with left-sided breast cancer treated with 3D-CRT under vDIBH, receiving 26 Gy in five fractions. Target volumes and organs at risk (OARs) were contoured on vDIBH CT scans. Treatment planning was performed using tangential fields. Dosimetric parameters for the planning target volume (PTV), heart, ipsilateral lung, contralateral breast, and spinal cord were evaluated using dose-volume histograms (DVHs). Reproducibility of vDIBH was ensured by using in-room lasers, skin tattoos, and cine-mode imaging for intrafraction verification. Results Mean PTV V95% was 97.74±1.74%, with a mean dose of 26.61±0.25 Gy. The mean heart dose was 3.97±0.82 Gy, with V25% at 13.28±3.44%. Ipsilateral lung mean dose (D<sub>mean</sub>) was 8.26±0.76 Gy, and V30% was 32.81±2.85%. Contralateral breast V5% was 5.19±7.06%. The spinal cord received a negligible dose (maximum dose {D<sub>max</sub>}​​​​ 0.49±0.12 Gy). All patients tolerated vDIBH well, with no delays or treatment interruptions. Conclusion 3D-CRT with vDIBH offers a practical, reproducible, and cost-effective approach for delivering hypofractionated radiotherapy in left-sided breast cancer. It ensures excellent target coverage while significantly reducing radiation dose to critical structures, such as the heart and lungs, supporting its use as a standard practice even in resource-constrained settings.

CureusVol. 17(10)
Tata Main Hospital (IN)
Openalex Percentile: Top 63%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.