Impact of Window-to-Wall Ratio (WWR) and Integrated Shading on Daylighting Performance for Visual Comfort in Nigerian Hotel Rooms

This study examines the impact of the Window-to-Wall Ratio (WWR) and integrated shading on the daylight performance and visual comfort of hotel rooms in Abuja, Nigeria, a tropical climate. The study employed a case study-based experimental design, utilizing simulation with Design Builder software. It employs two key metrics, Useful Daylight Illuminance (UDI) and Annual Sunlight Exposure (ASE), to analyse the performance trade-off between maximising natural light and mitigating glare and overheating. Findings indicate that as WWR increases, UDI improves, but ASE also rises, compromising visual comfort. A WWR between 40% and 60% with integrated shading is identified as the optimal range, striking a balance between sufficient daylight and manageable glare. The study demonstrates that while high WWRs enhance views, they are detrimental to occupant comfort without effective shading strategies, highlighting the critical role of façade design in sustainable building performance.

Authors

Institutions

Publication Details

Journal
Knowledge Web Multidisciplinary International Journal
Published
2025-10-02
DOI
https://doi.org/10.64488/kwmij.v1i2.17
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Window-to-Wall Ratio (WWR) and Integrated Shading on Daylighting Performance for Visual Comfort in Nigerian Hotel Rooms

Modi, Abalaka, Adamu, Vishigh et al.
Knowledge Web Multidisciplinary International Journal
Building Energy and Comfort Optimization
article

Impact of Window-to-Wall Ratio (WWR) and Integrated Shading on Daylighting Performance for Visual Comfort in Nigerian Hotel Rooms

Modi, Abalaka, Adamu, Vishigh, Abu, Dogara Ayenajeh
article en

Abstract

This study examines the impact of the Window-to-Wall Ratio (WWR) and integrated shading on the daylight performance and visual comfort of hotel rooms in Abuja, Nigeria, a tropical climate. The study employed a case study-based experimental design, utilizing simulation with Design Builder software. It employs two key metrics, Useful Daylight Illuminance (UDI) and Annual Sunlight Exposure (ASE), to analyse the performance trade-off between maximising natural light and mitigating glare and overheating. Findings indicate that as WWR increases, UDI improves, but ASE also rises, compromising visual comfort. A WWR between 40% and 60% with integrated shading is identified as the optimal range, striking a balance between sufficient daylight and manageable glare. The study demonstrates that while high WWRs enhance views, they are detrimental to occupant comfort without effective shading strategies, highlighting the critical role of façade design in sustainable building performance.

Knowledge Web Multidisciplinary International Journal
Benue State University (NG), Bingham University (NG), Federal University of Technology Minna (NG)
Openalex Percentile: Top 71%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Window-to-Wall Ratio (WWR) and Integrated Shading on Daylighting Performance for Visual Comfort in Nigerian Hotel Rooms — Modi, Abalaka, et al. · Knowledge Web Multidisciplinary International Journal (2025) | TGRS Research Map | TGRS