A novel RP-UPLC method development and validation for quantification of flubendazole in bulk and pharmaceutical dosage form

RP-UPLC approach was used to produce a straightforward, accurate, and exact method for estimating flubendazole.For chromatography, stationary phase C18 (4.6 x50 mm,5 m) was utilized.Acetonitrile and HPLC-grade water in 700:300 ratio was used as the mobile phase.The flow rate was kept at 0.45 ml/min, the detection wavelength was set at 230nm.six standard injections was used to study the system suitability characteristics, and the finding fell well within the acceptable range.The r2 value was 1.0000 after a linearity analysis was conducted at 80% to 120%level.The results showed that the precision was 0.66 for intermediate precision and 0.73 for repeatability.Respectively the LOD and LOQ values was found to be0.002 g/ml and 0.006 g/ml.

Authors

Publication Details

Journal
International Journal of Biomedical Investigation
Published
2025-01-01
DOI
https://doi.org/10.31531/2581-4745.1000164
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel RP-UPLC method development and validation for quantification of flubendazole in bulk and pharmaceutical dosage form

N Deattu, Mageshwari Anand, T. Hariharan, R Jawaharsamuvel et al.
International Journal of Biomedical Investigation
Analytical Methods in Pharmaceuticals
article

A novel RP-UPLC method development and validation for quantification of flubendazole in bulk and pharmaceutical dosage form

N Deattu, Mageshwari Anand, T. Hariharan, R Jawaharsamuvel, Sunitha PG, R Hemanath
article en

Abstract

RP-UPLC approach was used to produce a straightforward, accurate, and exact method for estimating flubendazole.For chromatography, stationary phase C18 (4.6 x50 mm,5 m) was utilized.Acetonitrile and HPLC-grade water in 700:300 ratio was used as the mobile phase.The flow rate was kept at 0.45 ml/min, the detection wavelength was set at 230nm.six standard injections was used to study the system suitability characteristics, and the finding fell well within the acceptable range.The r2 value was 1.0000 after a linearity analysis was conducted at 80% to 120%level.The results showed that the precision was 0.66 for intermediate precision and 0.73 for repeatability.Respectively the LOD and LOQ values was found to be0.002 g/ml and 0.006 g/ml.

International Journal of Biomedical InvestigationVol. 8(2)
Openalex Percentile: Top 69%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.