Synthesis and quaternization of poly(vinyl benzyl chloride-co-3-(methacryloyloxy)propyl] trimethoxy silane) for inhibiting bacterial growth on dental implants

Dental implants are widely used to treat tooth loss, but because their surface is exposed to the oral environment, they are vulnerable to microbial colonization. To combat this, recent efforts have focused on engineering implant surfaces with antimicrobial properties. This work involved the synthesis of an antimicrobial coating by quaternizing the copolymer of vinylbenzyl chloride (VBC) and [3-(Methacryloyloxy)propyl]trimethoxy silane (MPS) of varying alkyl chain lengths. The MPS-VBC copolymer was synthesized using free radical polymerization, and quaternized to form ammonium salts of varying chain length ( n ): Trimethylamine (n = 1) , Triethylamine ( n = 2 ) and N,N -Dimethyl octylamine ( n = 8 ). The quaternized ammonium salts (QAS) were characterized using 1 H NMR and FTIR spectroscopies. The antimicrobial effects of the QAS having different chain lengths were tested against both grampositive and gram-negative bacteria using different concentrations. The QAS with a chain length of n = 8 achieved a 99.9999 % reduction in E. coli and S. agalactiae , and a 99.99 % reduction in S. aureus . In contrast, QAS with shorter chain lengths (n = 1,2 ) showed no reduction in bacterial cells. The minimum inhibitory concentration (MIC) was found to be less than 10 mg/mL for all strains used in this study. The toxicity of our synthesized QAS was evaluated using Glutathione S-transferase (GST) activity. The QAS showed no cytotoxicity at MIC and MBC concentrations. This study opens pathways for using QAS in dental and oral pathways as they proved to be non-toxic when used orally. • An antimicrobial coating for dental applications using quaternized (VBC -co- MPS) were synthesized. • The antimicrobial efficacy with respect to chain length was investigated against E. coli, S. agalactiae and S. aureus . • Cytotoxicity was assessed using Glutathione S-transferase (GST) activity as a biomarker. • GST activity of the QAS confirmed no cytotoxicity at MIC concentrations.

Authors

Institutions

Publication Details

Journal
Materials Letters
Published
2025-10-02
DOI
https://doi.org/10.1016/j.matlet.2025.139578
Primary Topic
Antimicrobial agents and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis and quaternization of poly(vinyl benzyl chloride-co-3-(methacryloyloxy)propyl] trimethoxy silane) for inhibiting bacterial growth on dental implants

Amin S. Rizkalla, Paul A. Charpentier, Kazi Naziba Tahsin, D. Watson et al.
Materials Letters
Antimicrobial agents and applications
article

Synthesis and quaternization of poly(vinyl benzyl chloride-co-3-(methacryloyloxy)propyl] trimethoxy silane) for inhibiting bacterial growth on dental implants

Amin S. Rizkalla, Paul A. Charpentier, Kazi Naziba Tahsin, D. Watson, Wan Xu
article en

Abstract

Dental implants are widely used to treat tooth loss, but because their surface is exposed to the oral environment, they are vulnerable to microbial colonization. To combat this, recent efforts have focused on engineering implant surfaces with antimicrobial properties. This work involved the synthesis of an antimicrobial coating by quaternizing the copolymer of vinylbenzyl chloride (VBC) and [3-(Methacryloyloxy)propyl]trimethoxy silane (MPS) of varying alkyl chain lengths. The MPS-VBC copolymer was synthesized using free radical polymerization, and quaternized to form ammonium salts of varying chain length ( n ): Trimethylamine (n = 1) , Triethylamine ( n = 2 ) and N,N -Dimethyl octylamine ( n = 8 ). The quaternized ammonium salts (QAS) were characterized using 1 H NMR and FTIR spectroscopies. The antimicrobial effects of the QAS having different chain lengths were tested against both grampositive and gram-negative bacteria using different concentrations. The QAS with a chain length of n = 8 achieved a 99.9999 % reduction in E. coli and S. agalactiae , and a 99.99 % reduction in S. aureus . In contrast, QAS with shorter chain lengths (n = 1,2 ) showed no reduction in bacterial cells. The minimum inhibitory concentration (MIC) was found to be less than 10 mg/mL for all strains used in this study. The toxicity of our synthesized QAS was evaluated using Glutathione S-transferase (GST) activity. The QAS showed no cytotoxicity at MIC and MBC concentrations. This study opens pathways for using QAS in dental and oral pathways as they proved to be non-toxic when used orally. • An antimicrobial coating for dental applications using quaternized (VBC -co- MPS) were synthesized. • The antimicrobial efficacy with respect to chain length was investigated against E. coli, S. agalactiae and S. aureus . • Cytotoxicity was assessed using Glutathione S-transferase (GST) activity as a biomarker. • GST activity of the QAS confirmed no cytotoxicity at MIC concentrations.

Materials LettersVol. 404
Western University (CA)
Openalex Percentile: Top 79%
Antimicrobial agents and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.