Real-Time Monitoring of Particulate Matter in Indoor Sports Facilities Using Low-Cost Sensors: A Case Study in a Municipal Small-to-Medium-Sized Indoor Sport Facility

Indoor sports facilities present unique challenges for air quality management due to high crowd densities and limited ventilation. This study investigated air quality in a municipal athletic facility in Komotini, Greece, focusing on concentrations of airborne particulate matter (PM1.0, PM2.5, PM10), humidity, and temperature across spectator zones, under varying mask scenarios. Sensing devices were installed in the stands to collect high-frequency environmental data. The system, based on optical particle counters and cloud-enabled analytics, enabled real-time data capture and retrospective analysis. The main experiment investigated the impact of spectators wearing medical masks during two basketball games. The results show consistently elevated PM levels during games, often exceeding recommended international thresholds in the spectator area. Notably, the use of masks by spectators led to measurable reductions in PM1.0 and PM2.5 concentrations, because they seem to have limited the release of human-generated aerosols as well as the amount of movement among spectators, supporting their effectiveness in limiting fine particulate exposure in inadequately ventilated environments. Humidity emerged as a reliable indicator of occupancy and potential high-risk periods, making it a valuable parameter for real-time monitoring. The findings underscore the urgent need for improved ventilation strategies in small to medium-sized indoor sports facilities and support the deployment of low-cost sensor networks for actionable environmental health management.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2025-10-02
DOI
https://doi.org/10.3390/eng6100258
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Monitoring of Particulate Matter in Indoor Sports Facilities Using Low-Cost Sensors: A Case Study in a Municipal Small-to-Medium-Sized Indoor Sport Facility

Ioannis Karakasiliοtis, Maria Michalopoulou, Panagiotis Foteinakis, Christos Kokkotis et al.
Eng—Advances in Engineering
Air Quality Monitoring and Forecasting
article

Real-Time Monitoring of Particulate Matter in Indoor Sports Facilities Using Low-Cost Sensors: A Case Study in a Municipal Small-to-Medium-Sized Indoor Sport Facility

Ioannis Karakasiliοtis, Maria Michalopoulou, Panagiotis Foteinakis, Christos Kokkotis, Athanasios Chatzinikolaou, Paschalis Steiropoulos, Nikolaos Zaras, Alexandra Avloniti, Nikolaos Orestis Retzepis, Eleftheria Katsiri, Dimitrios Balampanos, Maria Protopapa, Dimitrios Pantazis, Panagiotis Aggelakis, Maria Emmanouilidou
article en

Abstract

Indoor sports facilities present unique challenges for air quality management due to high crowd densities and limited ventilation. This study investigated air quality in a municipal athletic facility in Komotini, Greece, focusing on concentrations of airborne particulate matter (PM1.0, PM2.5, PM10), humidity, and temperature across spectator zones, under varying mask scenarios. Sensing devices were installed in the stands to collect high-frequency environmental data. The system, based on optical particle counters and cloud-enabled analytics, enabled real-time data capture and retrospective analysis. The main experiment investigated the impact of spectators wearing medical masks during two basketball games. The results show consistently elevated PM levels during games, often exceeding recommended international thresholds in the spectator area. Notably, the use of masks by spectators led to measurable reductions in PM1.0 and PM2.5 concentrations, because they seem to have limited the release of human-generated aerosols as well as the amount of movement among spectators, supporting their effectiveness in limiting fine particulate exposure in inadequately ventilated environments. Humidity emerged as a reliable indicator of occupancy and potential high-risk periods, making it a valuable parameter for real-time monitoring. The findings underscore the urgent need for improved ventilation strategies in small to medium-sized indoor sports facilities and support the deployment of low-cost sensor networks for actionable environmental health management.

Eng—Advances in EngineeringVol. 6(10)
Democritus University of Thrace (GR)
Openalex Percentile: Top 75%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.