Capacitive coupled contactless conductivity detection combined with paper-based microfluidic for continuous human sweat rate measurement

Abstract Monitoring sweat rate provides valuable insights into an individual’s risk of dehydration, thermoregulation efficiency, and electrolyte balance, particularly relevant for workers in hot environments, athletes, and individuals with certain metabolic conditions. Traditional methods for measuring sweat rates, such as gravimetric techniques, are labor-intensive and unsuitable for real-time monitoring. Capacitive coupling contactless conductivity detection (C 4 D), a liquid conductivity-measurement technique, offers continuous signal output, high precision, rapid detection, and the advantage of preventing contamination of electrodes or samples. This study proposed an innovative approach integrating C 4 D with paper-based microfluidics for real-time measurement of sweat rate. Sweat secreted by sweat glands is directed through the microfluidic channels to the C 4 D electrodes, enabling continuous conductivity monitoring to assess sweat rate. The key parameters were systematically studied, including electrode layout, microfluidic channel structure, and excitation signal characteristics. Furthermore, the effects of sweat volume, electrolyte concentration, and sweating rate on detection accuracy were systematically investigated. To validate the method, we performed practical measurements using simulated sweat, demonstrating that the proposed technique is accurate, rapid, and effective for sweat rate monitoring. This work advances the integration of C 4 D with paper-based microfluidics, paving a new avenue for its practical application in sweat rate assessment and other health-related monitoring fields.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-10-02
DOI
https://doi.org/10.1088/1361-6501/ae0e89
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capacitive coupled contactless conductivity detection combined with paper-based microfluidic for continuous human sweat rate measurement

Mingpeng Yang, Jun Cai, Chaofan Wang, Xiaochen Lai et al.
1 citations
Measurement Science and Technology
Advanced Sensor and Energy Harvesting Materials
0.67
article

Capacitive coupled contactless conductivity detection combined with paper-based microfluidic for continuous human sweat rate measurement

Mingpeng Yang, Jun Cai, Chaofan Wang, Xiaochen Lai, Wangping Zhou
article en
1 citations

Abstract

Abstract Monitoring sweat rate provides valuable insights into an individual’s risk of dehydration, thermoregulation efficiency, and electrolyte balance, particularly relevant for workers in hot environments, athletes, and individuals with certain metabolic conditions. Traditional methods for measuring sweat rates, such as gravimetric techniques, are labor-intensive and unsuitable for real-time monitoring. Capacitive coupling contactless conductivity detection (C 4 D), a liquid conductivity-measurement technique, offers continuous signal output, high precision, rapid detection, and the advantage of preventing contamination of electrodes or samples. This study proposed an innovative approach integrating C 4 D with paper-based microfluidics for real-time measurement of sweat rate. Sweat secreted by sweat glands is directed through the microfluidic channels to the C 4 D electrodes, enabling continuous conductivity monitoring to assess sweat rate. The key parameters were systematically studied, including electrode layout, microfluidic channel structure, and excitation signal characteristics. Furthermore, the effects of sweat volume, electrolyte concentration, and sweating rate on detection accuracy were systematically investigated. To validate the method, we performed practical measurements using simulated sweat, demonstrating that the proposed technique is accurate, rapid, and effective for sweat rate monitoring. This work advances the integration of C 4 D with paper-based microfluidics, paving a new avenue for its practical application in sweat rate assessment and other health-related monitoring fields.

Measurement Science and TechnologyVol. 36(10)
Nanjing University of Information Science and Technology (CN), Nanjing University of Science and Technology (CN)
Openalex Percentile: Top 26%
Advanced Sensor and Energy Harvesting Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.