Low-noise environment for probing fundamental symmetries

Abstract We present the design and characterization of a low-noise environment for measuring the electron’s electric dipole moment (EDM) with a beam of molecules. To minimize magnetic Johnson noise from metals, the design features ceramic electric field plates housed in a glass vacuum chamber. To suppress external magnetic noise the apparatus is enclosed within a cylindrical four-layer mu-metal shield with a shielding factor exceeding 10 6 in one radial direction and 10 5 in the other. Finite element modelling shows that the difference between these shielding factors is due to imperfect joints between sections of mu-metal. Using atomic magnetometers to monitor the magnetic field inside the shield, we measure noise below 40 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 1 Hz and above, rising to 500 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 0.1 Hz. Analytical and numerical studies show that residual magnetic Johnson noise contributes approximately 13 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> . The background magnetic field averaged along the beamline is maintained below 3 pT, with typical gradients of a few nT m −1 . An electric field of 20 kV cm −1 is applied without discharges and with leakage currents below 1 nA. Each magnetometer measures the magnetic field correlated with the direction of the applied electric field with a precision of 0.11 fT in 104 h of data. These results demonstrate that the apparatus is suitable for measuring the electron EDM with precision at the 10 −31 e cm level. The design principles and characterization techniques presented here are broadly applicable to precision measurements probing fundamental symmetries in molecules, atoms, and neutrons.

Authors

Institutions

Publication Details

Journal
New Journal of Physics
Published
2025-10-01
DOI
https://doi.org/10.1088/1367-2630/ae0ea7
Primary Topic
Crystallography and Radiation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-noise environment for probing fundamental symmetries

Jongseok Lim, E. Wursten, Mark Ziemba, N. J. Fitch et al.
New Journal of Physics
Crystallography and Radiation Phenomena
article

Low-noise environment for probing fundamental symmetries

Jongseok Lim, E. Wursten, Mark Ziemba, N. J. Fitch, Rhys Jenkins, F. J. Collings, Sarah Y. Zheng, B. E. Sauer, Francesco Castellini, M. R. Tarbutt, J. M. Dyne
article en

Abstract

Abstract We present the design and characterization of a low-noise environment for measuring the electron’s electric dipole moment (EDM) with a beam of molecules. To minimize magnetic Johnson noise from metals, the design features ceramic electric field plates housed in a glass vacuum chamber. To suppress external magnetic noise the apparatus is enclosed within a cylindrical four-layer mu-metal shield with a shielding factor exceeding 10 6 in one radial direction and 10 5 in the other. Finite element modelling shows that the difference between these shielding factors is due to imperfect joints between sections of mu-metal. Using atomic magnetometers to monitor the magnetic field inside the shield, we measure noise below 40 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 1 Hz and above, rising to 500 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 0.1 Hz. Analytical and numerical studies show that residual magnetic Johnson noise contributes approximately 13 fT <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:msqrt> <mml:mtext>Hz</mml:mtext> </mml:msqrt> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> . The background magnetic field averaged along the beamline is maintained below 3 pT, with typical gradients of a few nT m −1 . An electric field of 20 kV cm −1 is applied without discharges and with leakage currents below 1 nA. Each magnetometer measures the magnetic field correlated with the direction of the applied electric field with a precision of 0.11 fT in 104 h of data. These results demonstrate that the apparatus is suitable for measuring the electron EDM with precision at the 10 −31 e cm level. The design principles and characterization techniques presented here are broadly applicable to precision measurements probing fundamental symmetries in molecules, atoms, and neutrons.

New Journal of PhysicsVol. 27(10)
Imperial College London (GB)
Openalex Percentile: Top 83%
Crystallography and Radiation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.