Rapid Screening of an Anti-interference Histamine Biosensor Based on Modulation-Driven Arrays on a Chip

This study proposes a modulated pixel array design integrated with a membrane, polyvinyl chloride (PVC), aimed at accurate determination of the histamine concentration. The system employs a high-sensitivity analog front-end coupled with a double offset cancellation comparator, achieving a wide concentration range of 0.05-100 μM, a sensitivity of 5.1 ADC units per μM, and a voltage gain of approximately 12.25 mV/μM. Upon exposure to histamine in the presence of diamine oxidase (DAO), the sensor exhibited a substantial signal change of 61.6%. A significant inhibition is observed when the interference level is substantially high, specifically at a histamine-to-putrescine/cadaverine/tyramine ratio of 1:20. The high sensitivity and specificity of the proposed pixel array make it an ideal candidate for on-site histamine detection in food and fish markets. Its portable design facilitates swift screening, enabling timely intervention to reduce histamine-related health hazards and improve the effectiveness of food safety monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Agricultural and Food Chemistry
Published
2025-10-02
DOI
https://doi.org/10.1021/acs.jafc.5c08561
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Screening of an Anti-interference Histamine Biosensor Based on Modulation-Driven Arrays on a Chip

Chun‐Ting Hsieh, Yun-Yu Hsieh, Wei‐Cheng Lin, Wei-Lun Yen
Journal of Agricultural and Food Chemistry
Biosensors and Analytical Detection
article

Rapid Screening of an Anti-interference Histamine Biosensor Based on Modulation-Driven Arrays on a Chip

Chun‐Ting Hsieh, Yun-Yu Hsieh, Wei‐Cheng Lin, Wei-Lun Yen
article en

Abstract

This study proposes a modulated pixel array design integrated with a membrane, polyvinyl chloride (PVC), aimed at accurate determination of the histamine concentration. The system employs a high-sensitivity analog front-end coupled with a double offset cancellation comparator, achieving a wide concentration range of 0.05-100 μM, a sensitivity of 5.1 ADC units per μM, and a voltage gain of approximately 12.25 mV/μM. Upon exposure to histamine in the presence of diamine oxidase (DAO), the sensor exhibited a substantial signal change of 61.6%. A significant inhibition is observed when the interference level is substantially high, specifically at a histamine-to-putrescine/cadaverine/tyramine ratio of 1:20. The high sensitivity and specificity of the proposed pixel array make it an ideal candidate for on-site histamine detection in food and fish markets. Its portable design facilitates swift screening, enabling timely intervention to reduce histamine-related health hazards and improve the effectiveness of food safety monitoring.

Journal of Agricultural and Food ChemistryVol. 73(41)
Memorial Hospital of South Bend (US), Chang Gung University (TW), Chang Gung Memorial Hospital (TW)
Openalex Percentile: Top 74%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.