A Novel Hyperspectral Imaging System for Whole Corn Ear Analysis and Aflatoxin Detection

Highlights Development of a whole corn ear hyperspectral imaging system. Field experiment found 25% inoculation with highest aflatoxin contamination. 80% detection accuracy for whole corn ear aflatoxin detection with NDFI method. Fluorescence peak shift observed for fungus infected and aflatoxin contaminated samples. ABSTRACT. Corn is the most widely cultivated crop in the United States and accounts for approximately one-third of total world production. Inspection of whole corn ears under field conditions is important during preharvest scouting because it is crucial for farmers to assess the cleanliness of the crop at harvest and for corn breeders to evaluate postharvest traits. This paper reports on aflatoxin contamination detection in whole corn ears using a novel hyperspectral imaging system for whole corn ear imaging. The hyperspectral imaging system employs pushbroom line-scanning uniquely with a rotational stage, enabling the acquisition of a flattened, two-dimensional spectral image of the entire ear surface from the 3D ear body. Inoculation experiments were conducted to obtain corn ears contaminated with aflatoxin in the field. Specifically, four treatments were implemented including Control, Control Pierced, inoculation of 25%, and 100% of Aspergillus flavus (AF13) inoculum concentrations. Fifty ears were harvested for each treatment for analysis. Each ear was imaged under ultraviolet light (365 nm) for excited fluorescence hyperspectral data acquisition and subsequently analyzed chemically for aflatoxin concentration. Image analysis was based on a rapid spectral index method, Normalized Fluorescence Difference Index (NDFI), using wavelengths at 537 and 437 nm for NDFI calculations. It was found that both inoculated treatments were severely contaminated with aflatoxin, with the 25% inoculation treatment having the highest aflatoxin concentration. A fluorescence peak shift was observed for the contaminated pixels. The clean control pixels had a fluorescence peak at 478 nm. The fluorescence peaks for the contaminated pixels were at 506-516 nm. When using 20 ppb (parts per billion) as a threshold for aflatoxin detection, the overall detection accuracy reached 80%, with the Control Pierced group achieving the highest accuracy of 86%. Although the study found no direct correlation between the number of detected “hot pixels” and measured aflatoxin concentration, as few as ten pixels would classify an ear as contaminated at the 20-ppb threshold using the NDFI algorithm. This research is the first to report on the use of the kernel crown fluorescence for aflatoxin detection and highlights the potential of whole-ear hyperspectral imaging for non-invasive contamination screening and morphological traits analysis in corn breeding. Keywords: Aflatoxin detection, Aspergillus flavus inoculation, Detection accuracy, Fluorescence peak shift, Whole corn ear hyperspectral imaging.

Authors

Publication Details

Journal
Journal of the ASABE
Published
2025-01-01
DOI
https://doi.org/10.13031/ja.16447
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Hyperspectral Imaging System for Whole Corn Ear Analysis and Aflatoxin Detection

Zuzana Hruska, Haibo Yao, Kanniah Rajasekaran, Daniel Jeffers
Journal of the ASABE
Spectroscopy and Chemometric Analyses
article

A Novel Hyperspectral Imaging System for Whole Corn Ear Analysis and Aflatoxin Detection

Zuzana Hruska, Haibo Yao, Kanniah Rajasekaran, Daniel Jeffers
article en

Abstract

Highlights Development of a whole corn ear hyperspectral imaging system. Field experiment found 25% inoculation with highest aflatoxin contamination. 80% detection accuracy for whole corn ear aflatoxin detection with NDFI method. Fluorescence peak shift observed for fungus infected and aflatoxin contaminated samples. ABSTRACT. Corn is the most widely cultivated crop in the United States and accounts for approximately one-third of total world production. Inspection of whole corn ears under field conditions is important during preharvest scouting because it is crucial for farmers to assess the cleanliness of the crop at harvest and for corn breeders to evaluate postharvest traits. This paper reports on aflatoxin contamination detection in whole corn ears using a novel hyperspectral imaging system for whole corn ear imaging. The hyperspectral imaging system employs pushbroom line-scanning uniquely with a rotational stage, enabling the acquisition of a flattened, two-dimensional spectral image of the entire ear surface from the 3D ear body. Inoculation experiments were conducted to obtain corn ears contaminated with aflatoxin in the field. Specifically, four treatments were implemented including Control, Control Pierced, inoculation of 25%, and 100% of Aspergillus flavus (AF13) inoculum concentrations. Fifty ears were harvested for each treatment for analysis. Each ear was imaged under ultraviolet light (365 nm) for excited fluorescence hyperspectral data acquisition and subsequently analyzed chemically for aflatoxin concentration. Image analysis was based on a rapid spectral index method, Normalized Fluorescence Difference Index (NDFI), using wavelengths at 537 and 437 nm for NDFI calculations. It was found that both inoculated treatments were severely contaminated with aflatoxin, with the 25% inoculation treatment having the highest aflatoxin concentration. A fluorescence peak shift was observed for the contaminated pixels. The clean control pixels had a fluorescence peak at 478 nm. The fluorescence peaks for the contaminated pixels were at 506-516 nm. When using 20 ppb (parts per billion) as a threshold for aflatoxin detection, the overall detection accuracy reached 80%, with the Control Pierced group achieving the highest accuracy of 86%. Although the study found no direct correlation between the number of detected “hot pixels” and measured aflatoxin concentration, as few as ten pixels would classify an ear as contaminated at the 20-ppb threshold using the NDFI algorithm. This research is the first to report on the use of the kernel crown fluorescence for aflatoxin detection and highlights the potential of whole-ear hyperspectral imaging for non-invasive contamination screening and morphological traits analysis in corn breeding. Keywords: Aflatoxin detection, Aspergillus flavus inoculation, Detection accuracy, Fluorescence peak shift, Whole corn ear hyperspectral imaging.

Journal of the ASABEVol. 68(5)
U.S. Department of Agriculture, Bill and Melinda Gates Foundation, Agricultural Research Service
Openalex Percentile: Top 69%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.