Reclosable Bidirectional Z-Source DC Circuit Breaker Suppressing Source-Side Fault Reflection and Reverse Recovery Spikes

In this article, a new bidirectional dc circuit breaker (DCCB) topology based on Z-source principles is presented. The new DCCB topology is featured with the reprotection capability and safely protects the dc source and load even when a utility controller tries to reengage the DCCB with an uncleared fault. Our topology is efficient as it only includes one semiconductor device in its current path during normal operation and is symmetrically built to provide bidirectionality. With an additional current path for a fault, our new DCCB suppresses the reflection of the fault current onto the source side, enhancing equipment protection. Detailed mathematical models are built in this article to analyze the protection mechanism, operation performance, and short-circuit fault responses. This article also discusses how to expedite the fault-clearing and reclosing processes. In addition, this article explores the impact of the reverse recovery of semiconductor devices in DCCBs and provides a mitigation strategy. A laboratory-scale prototype is built to validate the theoretical analyses and verify the benefits of the proposed bidirectional dc circuit breaker topology.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2025-10-02
DOI
https://doi.org/10.1109/tie.2025.3594420
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reclosable Bidirectional Z-Source DC Circuit Breaker Suppressing Source-Side Fault Reflection and Reverse Recovery Spikes

Jinli Zhu, Jinyeong Moon, Ki-Dong Song, Yeon-Ho Oh et al.
IEEE Transactions on Industrial Electronics
HVDC Systems and Fault Protection
article

Reclosable Bidirectional Z-Source DC Circuit Breaker Suppressing Source-Side Fault Reflection and Reverse Recovery Spikes

Jinli Zhu, Jinyeong Moon, Ki-Dong Song, Yeon-Ho Oh, Hyun-Mo Ahn, Min Gao, Jun-Kyu Park
article en

Abstract

In this article, a new bidirectional dc circuit breaker (DCCB) topology based on Z-source principles is presented. The new DCCB topology is featured with the reprotection capability and safely protects the dc source and load even when a utility controller tries to reengage the DCCB with an uncleared fault. Our topology is efficient as it only includes one semiconductor device in its current path during normal operation and is symmetrically built to provide bidirectionality. With an additional current path for a fault, our new DCCB suppresses the reflection of the fault current onto the source side, enhancing equipment protection. Detailed mathematical models are built in this article to analyze the protection mechanism, operation performance, and short-circuit fault responses. This article also discusses how to expedite the fault-clearing and reclosing processes. In addition, this article explores the impact of the reverse recovery of semiconductor devices in DCCBs and provides a mitigation strategy. A laboratory-scale prototype is built to validate the theoretical analyses and verify the benefits of the proposed bidirectional dc circuit breaker topology.

IEEE Transactions on Industrial ElectronicsVol. 73(2)
Florida State University (US), University of Pittsburgh (US), Korea Electrotechnology Research Institute (KR)
Openalex Percentile: Top 73%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reclosable Bidirectional Z-Source DC Circuit Breaker Suppressing Source-Side Fault Reflection and Reverse Recovery Spikes — Jinli Zhu, Jinyeong Moon, et al. · IEEE Transactions on Industrial Electronics (2025) | TGRS Research Map | TGRS