A Synchronous Rectification Method for 6.78 MHz Applications

Synchronous rectification is routinely used in numerous applications below the megahertz range. However, with the rapid advancement of semiconductor technologies, particularly gallium nitride devices that support significantly higher switching frequencies, synchronous rectification becomes an attractive alternative for specific applications, such as inductive power transfer systems. Nevertheless, its operation at higher frequencies presents significant challenges due to the propagation delays of the control circuitry and the associated switching losses. This article presents a novel synchronous rectification method for 6.78 MHz inductive power transfer systems, in which a phase-locked loop is employed to compensate for all circuit delays, enabling zero-current switching. The adaptive dead-time capability of the method allows zero-voltage switching for a wide load range, minimizing not only the conduction losses of the rectifier but also the switching losses. The proposed method is implemented on a GaN-based half-bridge class DE rectifier using discrete and off-the-shelf components only.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-10-02
DOI
https://doi.org/10.1109/tpel.2025.3617321
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Synchronous Rectification Method for 6.78 MHz Applications

I. López, Dražen Dujić, Jiasheng Huang
IEEE Transactions on Power Electronics
Electromagnetic Compatibility and Noise Suppression
article

A Synchronous Rectification Method for 6.78 MHz Applications

I. López, Dražen Dujić, Jiasheng Huang
article en

Abstract

Synchronous rectification is routinely used in numerous applications below the megahertz range. However, with the rapid advancement of semiconductor technologies, particularly gallium nitride devices that support significantly higher switching frequencies, synchronous rectification becomes an attractive alternative for specific applications, such as inductive power transfer systems. Nevertheless, its operation at higher frequencies presents significant challenges due to the propagation delays of the control circuitry and the associated switching losses. This article presents a novel synchronous rectification method for 6.78 MHz inductive power transfer systems, in which a phase-locked loop is employed to compensate for all circuit delays, enabling zero-current switching. The adaptive dead-time capability of the method allows zero-voltage switching for a wide load range, minimizing not only the conduction losses of the rectifier but also the switching losses. The proposed method is implemented on a GaN-based half-bridge class DE rectifier using discrete and off-the-shelf components only.

IEEE Transactions on Power ElectronicsVol. 41(3)
École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 73%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Synchronous Rectification Method for 6.78 MHz Applications — I. López, Dražen Dujić, et al. · IEEE Transactions on Power Electronics (2025) | TGRS Research Map | TGRS