Improving the Quadrupole to Ion Mobility Region in a Digital Quadrupole/Ion Mobility/Orbitrap Mass Spectrometer

A quadrupole/drift tube ion mobility/Orbitrap instrument requires pumping from atmosphere to 10<sup>-5</sup> Torr in the quadrupole analyzer region, back to 1 Torr for the drift tube, and a return to 10<sup>-5</sup> Torr for the Orbitrap high vacuum region. The Orbitrap high vacuum region contains the transfer multipole, C-trap, and HCD cell. Insufficient pumping between the drift tube and quadrupole leads to helium in the quadrupole analyzer chamber which compromises performance. Additional vacuum regions were added between the drift tube and the analyzer chamber to maintain the analyzer pressure below 5.5 × 10<sup>-5</sup> Torr with the drift tube pressurized to 1.5 Torr of He. In this configuration, the isolation of a single charge state of C-reactive protein (<i>m</i>/<i>z</i> 5,000) was demonstrated. Fourier transform ion mobility spectra were acquired with the quadrupole in full scan mode and in the isolation mode. Ion optic voltages were optimized for both helium and nitrogen bath gases in the drift tube so that minimal ion heating was observed entering the drift tube. These instrument modifications enable improved ion transfer efficiency, allowing for better ion isolation by the digital quadrupole ion mobility separation of large protein complexes, as illustrated by the 23+ and 24+ charge states of C-reactive protein.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-10-02
DOI
https://doi.org/10.1021/jasms.5c00142
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the Quadrupole to Ion Mobility Region in a Digital Quadrupole/Ion Mobility/Orbitrap Mass Spectrometer

Gordon Anderson, Robert Schrader, David H. Russell, Katherine J. Evans
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Improving the Quadrupole to Ion Mobility Region in a Digital Quadrupole/Ion Mobility/Orbitrap Mass Spectrometer

Gordon Anderson, Robert Schrader, David H. Russell, Katherine J. Evans
article en

Abstract

A quadrupole/drift tube ion mobility/Orbitrap instrument requires pumping from atmosphere to 10<sup>-5</sup> Torr in the quadrupole analyzer region, back to 1 Torr for the drift tube, and a return to 10<sup>-5</sup> Torr for the Orbitrap high vacuum region. The Orbitrap high vacuum region contains the transfer multipole, C-trap, and HCD cell. Insufficient pumping between the drift tube and quadrupole leads to helium in the quadrupole analyzer chamber which compromises performance. Additional vacuum regions were added between the drift tube and the analyzer chamber to maintain the analyzer pressure below 5.5 × 10<sup>-5</sup> Torr with the drift tube pressurized to 1.5 Torr of He. In this configuration, the isolation of a single charge state of C-reactive protein (<i>m</i>/<i>z</i> 5,000) was demonstrated. Fourier transform ion mobility spectra were acquired with the quadrupole in full scan mode and in the isolation mode. Ion optic voltages were optimized for both helium and nitrogen bath gases in the drift tube so that minimal ion heating was observed entering the drift tube. These instrument modifications enable improved ion transfer efficiency, allowing for better ion isolation by the digital quadrupole ion mobility separation of large protein complexes, as illustrated by the 23+ and 24+ charge states of C-reactive protein.

Journal of the American Society for Mass SpectrometryVol. 36(11)
Mitchell Institute (US), Custom Electronics (United States) (US), Texas A&M University (US)
Openalex Percentile: Top 74%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving the Quadrupole to Ion Mobility Region in a Digital Quadrupole/Ion Mobility/Orbitrap Mass Spectrometer — Gordon Anderson, Robert Schrader, et al. · Journal of the American Society for Mass Spectrometry (2025) | TGRS Research Map | TGRS