Qualification of the Disinfection Efficacy of an Ultraviolet Autonomous Robot for Use in Pharmaceutical Clean Rooms.

The aim of this study was to evaluate the efficacy of a UV-C disinfection robot intended for use on various cleanroom surfaces in the manufacturing facilities at AstraZeneca against a panel of different microorganisms. The studies performed used a method based on the Surface Challenge Test Method EN 13697² to evaluate the reduction in microbial viability after an inoculated surface was exposed to a with a light source emitting 254nm UV-C energy. In this surface challenge test, representative microorganisms were seeded onto coupons representing typical surfaces found in the cleanroom manufacturing areas. The inoculated coupons were treated with the UV-C light source at multiple dose-levels (mJ/cm²) to generate a death curve per organism, representing the required dose to achieve the desired log reduction as per USP<1072>¹¹ for disinfectant efficacy. The UV-C light source was tested against a panel of five American Type Culture Collection (ATCC) organisms (Pseudomonas paraeruginosa, Staphylococcus aureus, Bacillus spizizenii, Candida albicans and Aspergillus brasiliensis) and environmental isolates (Micrococcus luteus, Moraxella osloensis, Bacillus Cereus & Penicillium chrysogenum) selected from major AstraZeneca sites, which included those likely to present the greatest challenge to the effectiveness of the UV-C. The robot was qualified and shown to be suitable for use and can achieve a 3-log reduction for bacteria and 2-log reduction for spores depending on the dose applied. The dose selected by AstraZeneca was 100 mJ/cm² which represented the most practicable dose for the majority of clean room isolates with a higher dose reserved for use if adverse events for moulds or bacterial spores were recovered.

Authors

Institutions

Publication Details

Journal
European journal of parenteral & pharmaceutical sciences
Published
2025-10-02
DOI
https://doi.org/10.37521/ejpps30307
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Qualification of the Disinfection Efficacy of an Ultraviolet Autonomous Robot for Use in Pharmaceutical Clean Rooms.

Karen Capper, Sean Capper, C.E. Cooke, J Bright et al.
European journal of parenteral & pharmaceutical sciences
Innovative Microfluidic and Catalytic Techniques Innovation
article

Qualification of the Disinfection Efficacy of an Ultraviolet Autonomous Robot for Use in Pharmaceutical Clean Rooms.

Karen Capper, Sean Capper, C.E. Cooke, J Bright, A Gravett, V Hamers
article en

Abstract

The aim of this study was to evaluate the efficacy of a UV-C disinfection robot intended for use on various cleanroom surfaces in the manufacturing facilities at AstraZeneca against a panel of different microorganisms. The studies performed used a method based on the Surface Challenge Test Method EN 13697² to evaluate the reduction in microbial viability after an inoculated surface was exposed to a with a light source emitting 254nm UV-C energy. In this surface challenge test, representative microorganisms were seeded onto coupons representing typical surfaces found in the cleanroom manufacturing areas. The inoculated coupons were treated with the UV-C light source at multiple dose-levels (mJ/cm²) to generate a death curve per organism, representing the required dose to achieve the desired log reduction as per USP<1072>¹¹ for disinfectant efficacy. The UV-C light source was tested against a panel of five American Type Culture Collection (ATCC) organisms (Pseudomonas paraeruginosa, Staphylococcus aureus, Bacillus spizizenii, Candida albicans and Aspergillus brasiliensis) and environmental isolates (Micrococcus luteus, Moraxella osloensis, Bacillus Cereus & Penicillium chrysogenum) selected from major AstraZeneca sites, which included those likely to present the greatest challenge to the effectiveness of the UV-C. The robot was qualified and shown to be suitable for use and can achieve a 3-log reduction for bacteria and 2-log reduction for spores depending on the dose applied. The dose selected by AstraZeneca was 100 mJ/cm² which represented the most practicable dose for the majority of clean room isolates with a higher dose reserved for use if adverse events for moulds or bacterial spores were recovered.

European journal of parenteral & pharmaceutical sciences
AstraZeneca (Brazil) (BR)
Openalex Percentile: Top 74%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Qualification of the Disinfection Efficacy of an Ultraviolet Autonomous Robot for Use in Pharmaceutical Clean Rooms. — Karen Capper, Sean Capper, et al. · European journal of parenteral & pharmaceutical sciences (2025) | TGRS Research Map | TGRS