Simplifying the Assessment of Coronary Artery Stenosis by Enhancing Instantaneous Wave-Free Ratio

Background and objective The intermediate range of instantaneous wave-free ratio (iFR) measurements presents various diagnostic uncertainties. This study aimed to evaluate contrast-enhanced iFR (iFRc) to determine its correlation with fractional flow reserve (FFR). Our objective was to assess whether iFRc improves diagnostic alignment with FFR in coronary artery stenosis with intermediate iFR values (0.86-0.93). Patients and methods Thirty patients with intermediate iFR values were enrolled. The measurements included resting Pd/Pa, standard iFR, iFRc, and adenosine-mediated FFR. Detailed procedural protocols, including the type of pressure wire, guiding catheter, and contrast administration, were standardized. Results Pearson correlation between iFR and FFR was moderate (r = 0.578, p < 0.001), while iFRc showed a stronger correlation (r = 0.710, p < 0.001). The receiver operating characteristic (ROC) analysis demonstrated superior diagnostic performance for iFRc (area under the ROC curve (AUC) = 0.922, 95% confidence interval (CI): 0.799-1.0) compared with iFR (AUC = 0.856, 95% CI: 0.656-1.0). Optimal iFRc cutoff ≤0.88 yielded 88.9% sensitivity (95% CI: 51.8-99.7), 96% specificity (95% CI: 79.7-99.9), 88.9% positive predictive value (PPV) (95% CI: 51.8-99.7), and 96% negative predictive value (NPV) (95% CI: 79.7-99.9). Conclusions iFRc improves diagnostic certainty in intermediate iFR values and shows strong concordance with FFR. However, the findings are hypothesis-generating and warrant larger, multicenter validation studies.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-02
DOI
https://doi.org/10.7759/cureus.93710
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplifying the Assessment of Coronary Artery Stenosis by Enhancing Instantaneous Wave-Free Ratio

Khaled Elkhashab, Eman Mahmoud, A. William, Moustafa Kamal Eldin Ibrahim Khalil Saad et al.
Cureus
Coronary Interventions and Diagnostics
article

Simplifying the Assessment of Coronary Artery Stenosis by Enhancing Instantaneous Wave-Free Ratio

Khaled Elkhashab, Eman Mahmoud, A. William, Moustafa Kamal Eldin Ibrahim Khalil Saad, Mohamed Shaban Hashem Mahmoud, Bassem Zaref Fouad
article en

Abstract

Background and objective The intermediate range of instantaneous wave-free ratio (iFR) measurements presents various diagnostic uncertainties. This study aimed to evaluate contrast-enhanced iFR (iFRc) to determine its correlation with fractional flow reserve (FFR). Our objective was to assess whether iFRc improves diagnostic alignment with FFR in coronary artery stenosis with intermediate iFR values (0.86-0.93). Patients and methods Thirty patients with intermediate iFR values were enrolled. The measurements included resting Pd/Pa, standard iFR, iFRc, and adenosine-mediated FFR. Detailed procedural protocols, including the type of pressure wire, guiding catheter, and contrast administration, were standardized. Results Pearson correlation between iFR and FFR was moderate (r = 0.578, p < 0.001), while iFRc showed a stronger correlation (r = 0.710, p < 0.001). The receiver operating characteristic (ROC) analysis demonstrated superior diagnostic performance for iFRc (area under the ROC curve (AUC) = 0.922, 95% confidence interval (CI): 0.799-1.0) compared with iFR (AUC = 0.856, 95% CI: 0.656-1.0). Optimal iFRc cutoff ≤0.88 yielded 88.9% sensitivity (95% CI: 51.8-99.7), 96% specificity (95% CI: 79.7-99.9), 88.9% positive predictive value (PPV) (95% CI: 51.8-99.7), and 96% negative predictive value (NPV) (95% CI: 79.7-99.9). Conclusions iFRc improves diagnostic certainty in intermediate iFR values and shows strong concordance with FFR. However, the findings are hypothesis-generating and warrant larger, multicenter validation studies.

CureusVol. 17(10)
Countess of Chester Hospital NHS Foundation Trust (GB), National Heart Institute (EG), Fayoum University (EG)
Openalex Percentile: Top 57%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simplifying the Assessment of Coronary Artery Stenosis by Enhancing Instantaneous Wave-Free Ratio — Khaled Elkhashab, Eman Mahmoud, et al. · Cureus (2025) | TGRS Research Map | TGRS