Continuous once-through electrooxidation treatment using mixed metal oxide anode for bacterial disinfection

A novel electrooxidation (EO) unit was investigated for disinfecting wastewater, offering a promising alternative. This study continuously treated simulated bacterial wastewater using a mixed metal oxide (MMO) anode, mimicking hospital ward conditions. Optimal disinfection (96% bacterial inactivation) was achieved in continuous mode at a current density of 7.14 mA/cm<sup>2</sup>, 0.2 g/L NaCl, 9 min treatment time, and 40 mL/min flow rate. Real sewage wastewater achieved 92% inactivation at 8 min under these conditions. The MMO anode remained durable and effective after 300 cycles. EO presents a robust and affordable technology with an electrical consumption of 0.184 kWh/m<sup>3</sup> and an operational cost of $1.88/m<sup>3</sup>. These findings suggest this EO technique is a viable approach for decentralized wastewater treatment in hospital infectious wards, with the potential for real-world application.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-02
DOI
https://doi.org/10.1038/s41598-025-17636-4
Citations
1
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous once-through electrooxidation treatment using mixed metal oxide anode for bacterial disinfection

Diptiman Choudhury, Vijay Luxami, Anoop Verma, Aastha Palta et al.
1 citations
Scientific Reports
Advanced oxidation water treatment
0.82
article

Continuous once-through electrooxidation treatment using mixed metal oxide anode for bacterial disinfection

Diptiman Choudhury, Vijay Luxami, Anoop Verma, Aastha Palta, Poulomi Chandra
article en
1 citations

Abstract

A novel electrooxidation (EO) unit was investigated for disinfecting wastewater, offering a promising alternative. This study continuously treated simulated bacterial wastewater using a mixed metal oxide (MMO) anode, mimicking hospital ward conditions. Optimal disinfection (96% bacterial inactivation) was achieved in continuous mode at a current density of 7.14 mA/cm<sup>2</sup>, 0.2 g/L NaCl, 9 min treatment time, and 40 mL/min flow rate. Real sewage wastewater achieved 92% inactivation at 8 min under these conditions. The MMO anode remained durable and effective after 300 cycles. EO presents a robust and affordable technology with an electrical consumption of 0.184 kWh/m<sup>3</sup> and an operational cost of $1.88/m<sup>3</sup>. These findings suggest this EO technique is a viable approach for decentralized wastewater treatment in hospital infectious wards, with the potential for real-world application.

Scientific ReportsVol. 15(1)
Chandigarh University (IN), Thapar Institute of Engineering & Technology (IN)
Indian Council of Medical Research, Indian Institute of Technology Roorkee, Thapar Institute of Engineering and Technology
Openalex Percentile: Top 22%
Advanced oxidation water treatment
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.