BiLSTM-Based Fault Anticipation for Predictive Activation of FRER in Time-Sensitive Industrial Networks
Frame Replication and Elimination for Reliability (FRER) in Time-Sensitive Networking (TSN) enhances fault tolerance by duplicating critical traffic across disjoint paths. However, always-on FRER configurations introduce persistent redundancy overhead, even under nominal network conditions. This paper proposes a predictive FRER activation framework that anticipates faults using a Key Performance Indicator (KPI)-driven bidirectional Long Short-Term Memory (BiLSTM) model. By continuously analyzing multivariate KPIs—such as latency, jitter, and retransmission rates—the model forecasts potential faults and proactively activates FRER. Redundancy is deactivated upon KPI recovery or after a defined minimum protection window, thereby reducing bandwidth usage without compromising reliability. The framework includes a Python-based simulation environment, a real-time visualization dashboard built with Streamlit, and a fully integrated runtime controller. The experimental results demonstrate substantial improvements in link utilization while preserving fault protection, highlighting the effectiveness of anticipatory redundancy strategies in industrial TSN environments.
Authors
- Utz Roedig (ORCID: https://orcid.org/0000-0002-4020-0889)
- Dirk Pesch (ORCID: https://orcid.org/0000-0001-9706-5705)
- Mohamed Seliem (ORCID: https://orcid.org/0000-0002-2132-9249)
- Cormac J. Sreenan (ORCID: https://orcid.org/0000-0002-0767-7888)
Institutions
- University College Cork (IE)
Publication Details
- Journal
- IoT
- Published
- 2025-10-02
- DOI
- https://doi.org/10.3390/iot6040060
- Primary Topic
- Network Time Synchronization Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00