Thrombolytic potential of the “hydrodynamic cavitation on a chip” concept: insights into clot degradation

Thrombolysis is essential for treating vascular conditions such as pulmonary embolism and deep vein thrombosis, yet current thrombolytic drug-based approaches have notable limitations in efficacy and safety. Hydrodynamic cavitation (HC) offers drug-free clot degradation through mechanical disruption. In this study, the effects of HC exposure on thrombolysis were investigated using a clot-on-a-chip (CoC) platform. In this regard, the thrombolytic potential of HC exposure was evaluated by analyses involving hemolysis and fibrinolysis. Furthermore, the results were compared with acoustic cavitation (AC), a widely studied alternative. According to the obtained results, HC exposure (482 kPa, 120 s) resulted in 12.1% released hemoglobin and a 53.4% reduction in clot mass. In contrast, AC exposure (24 kHz, 50% nominal output power, 30 s) led to a 1.3-fold greater mass reduction with 26.8% released hemoglobin, likely due to additional thermal effects. Morphological analyses revealed that HC treatment significantly reduced red blood cell density in a pressure- and time-dependent manner. Notably, HC treatment effectively eroded blood clots by hemolysis with slight fibrinolysis, whereas clot erosion in AC was primarily due to hemolysis. HC achieved thrombolysis comparable to or better than AC, offering a safer, more targeted strategy, especially for disease due to RBC-rich clots such as non-cardioembolic stroke. The findings will advance mechanistic understanding of cavitation-induced clot degradation and support HC's clinical potential for thrombosis treatment.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2025-10-02
DOI
https://doi.org/10.1039/d5lc00482a
Citations
1
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thrombolytic potential of the “hydrodynamic cavitation on a chip” concept: insights into clot degradation

E. Amani, Tuğrul Elverdi, Ünal Akar, Beyzanur Özogul et al.
1 citations
Lab on a Chip
Ultrasound and Cavitation Phenomena
0.52
article

Thrombolytic potential of the “hydrodynamic cavitation on a chip” concept: insights into clot degradation

E. Amani, Tuğrul Elverdi, Ünal Akar, Beyzanur Özogul, Dmitry Grishenkov, Seyedali Seyedmirzaei Sarraf, Morteza Ghorbani, Abuzer Alp Yetisgin, Ali Koşar, Rabia Mercimek
article en
1 citations

Abstract

Thrombolysis is essential for treating vascular conditions such as pulmonary embolism and deep vein thrombosis, yet current thrombolytic drug-based approaches have notable limitations in efficacy and safety. Hydrodynamic cavitation (HC) offers drug-free clot degradation through mechanical disruption. In this study, the effects of HC exposure on thrombolysis were investigated using a clot-on-a-chip (CoC) platform. In this regard, the thrombolytic potential of HC exposure was evaluated by analyses involving hemolysis and fibrinolysis. Furthermore, the results were compared with acoustic cavitation (AC), a widely studied alternative. According to the obtained results, HC exposure (482 kPa, 120 s) resulted in 12.1% released hemoglobin and a 53.4% reduction in clot mass. In contrast, AC exposure (24 kHz, 50% nominal output power, 30 s) led to a 1.3-fold greater mass reduction with 26.8% released hemoglobin, likely due to additional thermal effects. Morphological analyses revealed that HC treatment significantly reduced red blood cell density in a pressure- and time-dependent manner. Notably, HC treatment effectively eroded blood clots by hemolysis with slight fibrinolysis, whereas clot erosion in AC was primarily due to hemolysis. HC achieved thrombolysis comparable to or better than AC, offering a safer, more targeted strategy, especially for disease due to RBC-rich clots such as non-cardioembolic stroke. The findings will advance mechanistic understanding of cavitation-induced clot degradation and support HC's clinical potential for thrombosis treatment.

Lab on a ChipVol. 26(1)
Sabancı Üniversitesi (TR), Amirkabir University of Technology (IR), Lehigh University (US), Istanbul University-Cerrahpaşa (TR), KTH Royal Institute of Technology (SE)
Openalex Percentile: Top 32%
Ultrasound and Cavitation Phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.