Clinical validation of a deep learning tool for characterizing spinopelvic mobility in total hip arthroplasty

Radiographic measurement of patient-specific spinopelvic mobility is standard-of-care in total hip arthroplasty (THA). Current manual methods are time-consuming, subjective, and error-prone. This study utilized deep learning (DL) to classify functional positions and measure pelvic tilt (PT), sacral slope (SS) and lumbar lordotic angle (LLA). A DL pipeline integrating image classification, vertebra detection, and landmark detection was developed using data from an international joint registry, comprising 52,772 images for classification, 9,875 for object detection, and 25,249 for landmark detection. Performance was evaluated using area under the curve (AUC), F1 score, and mean absolute error (MAE). Accuracy was compared to annotations by three expert engineers and validated by two senior engineers and a surgeon. Radiographs were processed in 1.96 ± 0.04 s, achieving precision, recall, Receiver-operator-characteristic-AUC, and Precision-Recall-AUC metrics above 0.994. Anatomical landmark predictions resulted in errors of: PT: 1.6°±2.1°, SS: 3.3°±2.6°, LLA: 4.2°±3.2°. There was no significant difference in PT and LLA between expert engineers and the DL pipeline, and 0.5° difference in SS (p = 0.043). Clinical validation showed no difference in landmark rejection rates (p > 0.05). We developed and clinically validated a DL pipeline that accurately measures patient-specific spinopelvic mobility from lateral functional radiographs, providing a scalable method for routine characterization in THA patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-02
DOI
https://doi.org/10.1038/s41598-025-16824-6
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical validation of a deep learning tool for characterizing spinopelvic mobility in total hip arthroplasty

Gerard H. Smith, Sanjeev Gupta, Edgar A. Wakelin, J Pierrepont et al.
Scientific Reports
Orthopaedic implants and arthroplasty
article

Clinical validation of a deep learning tool for characterizing spinopelvic mobility in total hip arthroplasty

Gerard H. Smith, Sanjeev Gupta, Edgar A. Wakelin, J Pierrepont, Christopher Plaskos, Joseph J. Kavolus
article en

Abstract

Radiographic measurement of patient-specific spinopelvic mobility is standard-of-care in total hip arthroplasty (THA). Current manual methods are time-consuming, subjective, and error-prone. This study utilized deep learning (DL) to classify functional positions and measure pelvic tilt (PT), sacral slope (SS) and lumbar lordotic angle (LLA). A DL pipeline integrating image classification, vertebra detection, and landmark detection was developed using data from an international joint registry, comprising 52,772 images for classification, 9,875 for object detection, and 25,249 for landmark detection. Performance was evaluated using area under the curve (AUC), F1 score, and mean absolute error (MAE). Accuracy was compared to annotations by three expert engineers and validated by two senior engineers and a surgeon. Radiographs were processed in 1.96 ± 0.04 s, achieving precision, recall, Receiver-operator-characteristic-AUC, and Precision-Recall-AUC metrics above 0.994. Anatomical landmark predictions resulted in errors of: PT: 1.6°±2.1°, SS: 3.3°±2.6°, LLA: 4.2°±3.2°. There was no significant difference in PT and LLA between expert engineers and the DL pipeline, and 0.5° difference in SS (p = 0.043). Clinical validation showed no difference in landmark rejection rates (p > 0.05). We developed and clinically validated a DL pipeline that accurately measures patient-specific spinopelvic mobility from lateral functional radiographs, providing a scalable method for routine characterization in THA patients.

Scientific ReportsVol. 15(1)
Royal Prince Alfred Hospital (AU), New South Wales Department of Primary Industries (AU), Newton Wellesley Hospital (US), Olympus (Australia) (AU)
Openalex Percentile: Top 57%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.