Low Radiation Doses to Gross Tumor Volume in Metabolism Guided Lattice Irradiation Based on Lattice-01 Study: Dosimetric Evaluation and Potential Clinical Research Implication

<b>Purpose</b>: This paper aims to calculate the gross tumor volume (GTV) receiving low radiation doses in patients submitted to "metabolism-guided" lattice radiation therapy and relative possible implications with clinical outcomes. <b>Material and Methods</b>: We reviewed plans for treating voluminous masses via "metabolism-guided" LATTICE-01 irradiation. The aim was to deliver high-dose radiation to spherical deposits (vertices) within a bulky tumor mass. These were placed at tumor areas with differing PET metabolism. We evaluated the relationships between GTV volumes and dose-volumetric histograms (mean, maximum, minimum, and % GTV received 0.5, 1, 2, 3 Gy). <b>Results</b>: Sixty-two plans of treatment met the inclusion criteria as established. The median GTV volume was 315.9 cc (range = 10.54-2605.9 cc). A median of two Vertices was allocated within the GTVs (range 1-9) and were planned to receive a dose of ≥10 Gy/1 fraction (median 12 Gy, range 10-15 Gy). Median V3Gy percentage was 51.58% (range 2-100%), median V2Gy percentage was 67.80% (range 1.60-100%), median V1Gy percentage was 83.70% (range 0.80-100%), and median V0.5Gy percentage was 88.49% (range 17.60-100%). <b>Conclusions</b>: In the present series, we performed a dosimetric evaluation of the GTV's volume exposed to low doses during the metabolic guided lattice irradiation process. Combining high- and low-dose radiotherapy based on a spatially fractionated (LATTICE) approach could reactivate the immune system against cancer cells. These observations could be useful for planning prospective studies on immunotherapy combined with the lattice technique.

Authors

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2025-10-02
DOI
https://doi.org/10.3390/jpm15100470
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low Radiation Doses to Gross Tumor Volume in Metabolism Guided Lattice Irradiation Based on Lattice-01 Study: Dosimetric Evaluation and Potential Clinical Research Implication

Federico Chillari, Valeria Venuti, A. Brogna, Valentina Zagardo et al.
Journal of Personalized Medicine
Advanced Radiotherapy Techniques
article

Low Radiation Doses to Gross Tumor Volume in Metabolism Guided Lattice Irradiation Based on Lattice-01 Study: Dosimetric Evaluation and Potential Clinical Research Implication

Federico Chillari, Valeria Venuti, A. Brogna, Valentina Zagardo, Giuseppe Iatì, Gianluca Ferini, Stefano Pergolizzi, C. Siragusa, Silvana Parisi, Miriam Sciacca, Anna Santacaterina, Giacomo Ferrantelli
article en

Abstract

<b>Purpose</b>: This paper aims to calculate the gross tumor volume (GTV) receiving low radiation doses in patients submitted to "metabolism-guided" lattice radiation therapy and relative possible implications with clinical outcomes. <b>Material and Methods</b>: We reviewed plans for treating voluminous masses via "metabolism-guided" LATTICE-01 irradiation. The aim was to deliver high-dose radiation to spherical deposits (vertices) within a bulky tumor mass. These were placed at tumor areas with differing PET metabolism. We evaluated the relationships between GTV volumes and dose-volumetric histograms (mean, maximum, minimum, and % GTV received 0.5, 1, 2, 3 Gy). <b>Results</b>: Sixty-two plans of treatment met the inclusion criteria as established. The median GTV volume was 315.9 cc (range = 10.54-2605.9 cc). A median of two Vertices was allocated within the GTVs (range 1-9) and were planned to receive a dose of ≥10 Gy/1 fraction (median 12 Gy, range 10-15 Gy). Median V3Gy percentage was 51.58% (range 2-100%), median V2Gy percentage was 67.80% (range 1.60-100%), median V1Gy percentage was 83.70% (range 0.80-100%), and median V0.5Gy percentage was 88.49% (range 17.60-100%). <b>Conclusions</b>: In the present series, we performed a dosimetric evaluation of the GTV's volume exposed to low doses during the metabolic guided lattice irradiation process. Combining high- and low-dose radiotherapy based on a spatially fractionated (LATTICE) approach could reactivate the immune system against cancer cells. These observations could be useful for planning prospective studies on immunotherapy combined with the lattice technique.

Journal of Personalized MedicineVol. 15(10)
University of Messina (IT), Università degli Studi di Enna Kore (IT), University of Catania (IT), Ospedale Santa Chiara (IT), Hospital Madre Teresa (BR), Azienda Ospedaliera Universitaria Policlinico "G. Martino" (IT), Azienda Ospedaliera Ospedali Riuniti Papardo Piemonte (IT)
Openalex Percentile: Top 63%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.