Identification and Determination of Methylisothiazolinone and Chloromethylisothiazolinone in Cosmetics by Liquid Chromatography Tandem Mass Spectrometry

Broad-spectrum preservatives known as isothiazolinone biocides are frequently found in cosmetic, industrial, and household products. Certain isothiazolinones (methylisothiazolinone, MIT, and chloromethylisothiazolinone, CMIT) might result in eczema, edema, or allergic contact dermatitis by dermal contact or inhalation. This study aims to develop and validate the identification and determination method of a single MIT and MIT/CMIT mixture utilizing UPLC fitted with tandem mass spectrometry quadrupole time of flight (QTOF) for various beauty products. Several evaluations, including specificity, linearity, recovery, stability, precision, accuracy, determination of detection limit (LOD), and quantitation limit (LOQ) were conducted after some optimization processes by using LC-MS/MS QTOF. The MRM transition ion of MIT was m/z 116.0165 → 99.0091, 101.0215, and 84.9954. Meanwhile for CMIT was m/z 149.9775 → 134.9977, 86.9906, and 115.0447. MIT and CMIT were successfully distinguished and identified. The retention times of MIT and MCIT were detected at 4.53, and 5.25 min, respectively. Good selectivity was achieved by using the approach with resolution value greater than 1.5. The linearity range for single MIT was 375-1125 ng/mL, meanwhile for MIT/CMIT mixture resulted in 107.68-323.04 ng/mL for MIT and 295.36-886.08 for CMIT, respectively. Furthermore, the calibration curve approach was used to determine LOD acquired. In addition, LOQ over the LOD value was 0.00003%. These findings proved the suitability of the developed method to quantify MIT and CMIT in cosmetics. Samples of 21 cosmetic products, including soaps, shampoos, lotions, lipstick, and liquid cosmetics, from local markets and pharmacies were analysed using the developed method. Three of them were found to contain both single MIT or MIT/CMIT mixture. The technique and the data will help the Indonesian FDA to regulate the compounds used in cosmetics.

Authors

Institutions

Publication Details

Journal
INDONESIAN JOURNAL OF PHARMACY
Published
2025-09-22
DOI
https://doi.org/10.22146/ijp.16886
Primary Topic
Structural and Chemical Analysis of Organic and Inorganic Compounds
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification and Determination of Methylisothiazolinone and Chloromethylisothiazolinone in Cosmetics by Liquid Chromatography Tandem Mass Spectrometry

Nenden Solihatul Zannah, Endang Lukitaningsih, Sri Purwaningsih, Yustina Yustina
INDONESIAN JOURNAL OF PHARMACY
Structural and Chemical Analysis of Organic and Inorganic Compounds
article

Identification and Determination of Methylisothiazolinone and Chloromethylisothiazolinone in Cosmetics by Liquid Chromatography Tandem Mass Spectrometry

Nenden Solihatul Zannah, Endang Lukitaningsih, Sri Purwaningsih, Yustina Yustina
article en

Abstract

Broad-spectrum preservatives known as isothiazolinone biocides are frequently found in cosmetic, industrial, and household products. Certain isothiazolinones (methylisothiazolinone, MIT, and chloromethylisothiazolinone, CMIT) might result in eczema, edema, or allergic contact dermatitis by dermal contact or inhalation. This study aims to develop and validate the identification and determination method of a single MIT and MIT/CMIT mixture utilizing UPLC fitted with tandem mass spectrometry quadrupole time of flight (QTOF) for various beauty products. Several evaluations, including specificity, linearity, recovery, stability, precision, accuracy, determination of detection limit (LOD), and quantitation limit (LOQ) were conducted after some optimization processes by using LC-MS/MS QTOF. The MRM transition ion of MIT was m/z 116.0165 → 99.0091, 101.0215, and 84.9954. Meanwhile for CMIT was m/z 149.9775 → 134.9977, 86.9906, and 115.0447. MIT and CMIT were successfully distinguished and identified. The retention times of MIT and MCIT were detected at 4.53, and 5.25 min, respectively. Good selectivity was achieved by using the approach with resolution value greater than 1.5. The linearity range for single MIT was 375-1125 ng/mL, meanwhile for MIT/CMIT mixture resulted in 107.68-323.04 ng/mL for MIT and 295.36-886.08 for CMIT, respectively. Furthermore, the calibration curve approach was used to determine LOD acquired. In addition, LOQ over the LOD value was 0.00003%. These findings proved the suitability of the developed method to quantify MIT and CMIT in cosmetics. Samples of 21 cosmetic products, including soaps, shampoos, lotions, lipstick, and liquid cosmetics, from local markets and pharmacies were analysed using the developed method. Three of them were found to contain both single MIT or MIT/CMIT mixture. The technique and the data will help the Indonesian FDA to regulate the compounds used in cosmetics.

INDONESIAN JOURNAL OF PHARMACY
Universitas Gadjah Mada (ID), Food and Drug Administration (TH)
Universitas Gadjah Mada
Openalex Percentile: Top 79%
Structural and Chemical Analysis of Organic and Inorganic Compounds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.