B-074 Comprehensive Performance Evaluation of a Novel CLIA for Measurement of Vitamin D Across Diverse Clinical Conditions and Status Levels

Abstract Background Vitamin D (VitD) deficiency is a global health concern requiring precise measurement for diagnosis and management. Current CLIAs, including DiaSorin, Roche, Abbott, and Beckman-Coulter, are widely used but face challenges such as standardization issues, inter-laboratory variability, and interference from metabolites and binding proteins, emphasizing the need for improved assays. Methods This study assessed the analytical performance of the Mindray CL-900i® 25-OH VitD Total assay, comparing it with DiaSorin and Roche to evaluate its suitability as an alternative for clinical VitD quantification. A total of 345 serum samples, spanning a wide range of VitD levels and diverse health conditions (pregnancy, chronic kidney disease, osteoporosis), were analyzed using DiaSorin, Roche, and Mindray. Diagnostic metrics, including sensitivity, specificity, and positive predictive value (PPV), were calculated. Bland-Altman and Spearman’s rank correlation analyses were performed. Results All assays showed strong correlations. DiaSorin-Roche achieved r=0.92, AUC=0.96. Mindray-DiaSorin and Mindray-Rochecorrelations were r=0.92 and r=0.80 with AUCs of 0.97 and 0.90, respectively. Bland-Altman analysis revealed acceptable mean biases: Roche-DiaSorin (5.72± 8.71 ng/mL), Mindray-DiaSorin (5.32±11.0 ng/mL), and Mindray-Roche (11.0±15.9 ng/mL). The best cut-off for Mindray, derived from Youden’sindex, was >32 ng/mL, while DiaSorin’s was >30 ng/mL. Mindray demonstrated high specificity (99% vs. DiaSorin; 98% vs. Roche) and PPV (98% vs. both), ensuring robust identification of VitD sufficiency and reliable deficiency diagnoses when flagged positive. Conclusion The Mindray CL-900i® assay aligns closely with reference methods, particularly DiaSorin, offering a reliable alternative for clinical VitD quantification.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.472
Primary Topic
Vitamin D Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B-074 Comprehensive Performance Evaluation of a Novel CLIA for Measurement of Vitamin D Across Diverse Clinical Conditions and Status Levels

Ling Zhu
Clinical Chemistry
Vitamin D Research Studies
article

B-074 Comprehensive Performance Evaluation of a Novel CLIA for Measurement of Vitamin D Across Diverse Clinical Conditions and Status Levels

Ling Zhu
article en

Abstract

Abstract Background Vitamin D (VitD) deficiency is a global health concern requiring precise measurement for diagnosis and management. Current CLIAs, including DiaSorin, Roche, Abbott, and Beckman-Coulter, are widely used but face challenges such as standardization issues, inter-laboratory variability, and interference from metabolites and binding proteins, emphasizing the need for improved assays. Methods This study assessed the analytical performance of the Mindray CL-900i® 25-OH VitD Total assay, comparing it with DiaSorin and Roche to evaluate its suitability as an alternative for clinical VitD quantification. A total of 345 serum samples, spanning a wide range of VitD levels and diverse health conditions (pregnancy, chronic kidney disease, osteoporosis), were analyzed using DiaSorin, Roche, and Mindray. Diagnostic metrics, including sensitivity, specificity, and positive predictive value (PPV), were calculated. Bland-Altman and Spearman’s rank correlation analyses were performed. Results All assays showed strong correlations. DiaSorin-Roche achieved r=0.92, AUC=0.96. Mindray-DiaSorin and Mindray-Rochecorrelations were r=0.92 and r=0.80 with AUCs of 0.97 and 0.90, respectively. Bland-Altman analysis revealed acceptable mean biases: Roche-DiaSorin (5.72± 8.71 ng/mL), Mindray-DiaSorin (5.32±11.0 ng/mL), and Mindray-Roche (11.0±15.9 ng/mL). The best cut-off for Mindray, derived from Youden’sindex, was >32 ng/mL, while DiaSorin’s was >30 ng/mL. Mindray demonstrated high specificity (99% vs. DiaSorin; 98% vs. Roche) and PPV (98% vs. both), ensuring robust identification of VitD sufficiency and reliable deficiency diagnoses when flagged positive. Conclusion The Mindray CL-900i® assay aligns closely with reference methods, particularly DiaSorin, offering a reliable alternative for clinical VitD quantification.

Clinical ChemistryVol. 71(Supplement_1)
Mindray (China) (CN)
Openalex Percentile: Top 62%
Vitamin D Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.