B-172 Rapid Analysis of Clozapine and Norclozapine in Plasma for Clinical Research

Abstract Background Protein precipitation is combined with liquid chromatography (LC) and tandem mass spectrometry for high throughput analysis of clozapine (CLZ) and norclozapine (NCLZ), for use in clinical research. Methods Matrix-matched calibrators and quality control samples were prepared in human plasma, using stocks prepared from certified materials. Samples (50µL) were treated with internal standard in acetonitrile, and 20µL of supernatant was diluted with 30% methanol (aq). With an injection cycle of 1.2 minutes, the sample was separated by LC in a gradient of buffered water, methanol and isopropanol using a Waters XBridgeTM Premier BEHTM UPLCTM Column, on an ACQUITYTM UPLC I-Class FTN System, followed by detection using a XevoTM TQ-S micro Mass Spectrometer. Results Having verified the absence of significant carryover, the linear measurement interval (LMI) was determined to be 12-4946 ng/mL for CLZ and 4.5-3765 ng/mL for NCLZ, defined as the range with no significant 2nd/3rd order terms (p<0.05), r2=0.997 by linear regression, and measurable with =20% imprecision (relative standard deviation, RSD %) and =15% deviation from nominal concentrations. Total imprecision of measurement for four levels of controls within the LMI was =3.2% (n=25), with =4.8% deviation from nominal. The limit of detection and lower limit of quantification was 4.4 and 13.3 ng/mL for CLZ, and 14.7 and 44.5 ng/mL for NCLZ, determined by regression of five calibration datasets. Functional sensitivity experiments corroborated this by showing =85% recovery of compounds from pooled plasma enriched with 12.0 ng/mL CLZ and 4.5 ng/mL NCLZ, measurable with =20% imprecision (n=50). Internal standardization of CLZ and NCLZ with 2H4-CLZ was applied, which compensated for the negligible residual matrix effects in six plasma samples within the LMI, with mean recovery normalized to solvent standards of 100.3% for CLZ (range 99.0-100.8) and 104.1% for NCLZ (103.6-104.7). Agreement with comparator LC-MS/MS analytical methods was established, and EQA z-scores =2.00 for 11/11 distributions were achieved. Conclusion The analytical method meets performance requirements and is suitable for use in clinical research where high-throughput of samples is imperative. For Research Use Only. Not for Use in Diagnostic Procedures. XBridge, BEH, UPLC, ACQUITY, Xevo are trademarks of Waters Technologies Corporation.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.565
Primary Topic
Schizophrenia research and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B-172 Rapid Analysis of Clozapine and Norclozapine in Plasma for Clinical Research

S. Balloch, Samantha Roberts, Heather A. Brown, Gareth Hammond et al.
Clinical Chemistry
Schizophrenia research and treatment
article

B-172 Rapid Analysis of Clozapine and Norclozapine in Plasma for Clinical Research

S. Balloch, Samantha Roberts, Heather A. Brown, Gareth Hammond, Lisa Calton, Padhraic Rossiter
article en

Abstract

Abstract Background Protein precipitation is combined with liquid chromatography (LC) and tandem mass spectrometry for high throughput analysis of clozapine (CLZ) and norclozapine (NCLZ), for use in clinical research. Methods Matrix-matched calibrators and quality control samples were prepared in human plasma, using stocks prepared from certified materials. Samples (50µL) were treated with internal standard in acetonitrile, and 20µL of supernatant was diluted with 30% methanol (aq). With an injection cycle of 1.2 minutes, the sample was separated by LC in a gradient of buffered water, methanol and isopropanol using a Waters XBridgeTM Premier BEHTM UPLCTM Column, on an ACQUITYTM UPLC I-Class FTN System, followed by detection using a XevoTM TQ-S micro Mass Spectrometer. Results Having verified the absence of significant carryover, the linear measurement interval (LMI) was determined to be 12-4946 ng/mL for CLZ and 4.5-3765 ng/mL for NCLZ, defined as the range with no significant 2nd/3rd order terms (p<0.05), r2=0.997 by linear regression, and measurable with =20% imprecision (relative standard deviation, RSD %) and =15% deviation from nominal concentrations. Total imprecision of measurement for four levels of controls within the LMI was =3.2% (n=25), with =4.8% deviation from nominal. The limit of detection and lower limit of quantification was 4.4 and 13.3 ng/mL for CLZ, and 14.7 and 44.5 ng/mL for NCLZ, determined by regression of five calibration datasets. Functional sensitivity experiments corroborated this by showing =85% recovery of compounds from pooled plasma enriched with 12.0 ng/mL CLZ and 4.5 ng/mL NCLZ, measurable with =20% imprecision (n=50). Internal standardization of CLZ and NCLZ with 2H4-CLZ was applied, which compensated for the negligible residual matrix effects in six plasma samples within the LMI, with mean recovery normalized to solvent standards of 100.3% for CLZ (range 99.0-100.8) and 104.1% for NCLZ (103.6-104.7). Agreement with comparator LC-MS/MS analytical methods was established, and EQA z-scores =2.00 for 11/11 distributions were achieved. Conclusion The analytical method meets performance requirements and is suitable for use in clinical research where high-throughput of samples is imperative. For Research Use Only. Not for Use in Diagnostic Procedures. XBridge, BEH, UPLC, ACQUITY, Xevo are trademarks of Waters Technologies Corporation.

Clinical ChemistryVol. 71(Supplement_1)
Waters (United States) (US), Waterford Institute (US), University Hospital Waterford (IE), Waters (United Kingdom) (GB)
Openalex Percentile: Top 67%
Schizophrenia research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.