A-179 A Multi-Centre Assessment of Comparability of Hemolysis Indices on Automated Analyzers

Abstract Background Hemolysis is a prevalent preanalytical issue that compromises quality and patient safety during laboratory testing. It can interfere with sample analysis, leading to inaccurate results, sample rejection, and delayed patient treatment. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has identified hemolysis as a high-priority quality indicator, defined as the rate of samples with hemoglobin (Hgb) above 50 mg/dL (>0.5 g/L). Automated methods have improved hemolysis detection in serum/plasma samples. However, the internal calibration of automated methods for hemoglobin estimation (i.e. Hemolysis index) is usually not verified for accuracy against external standards by the end-user nor standardized across methods. This study aims to address this gap by comparing hemoglobin quantification using the serum indices application on automated chemistry analyzers versus a conventional spectrophotometric method that is validated for plasma free hemoglobin measurement. Methods Plasma samples (n=20) were analyzed at nine laboratories across the Greater Toronto Area in Canada. The plasma free Hgb concentrations in patient samples ranging from 5 to 450 mg/dL (0.05 to 4.50 g/L) were determined with the method of Khan SE et al. (Ann Clin Lab Sci. 1981;11(2):126-31) on Agilent Cary 60 UV/Vis spectrophotometer as the reference. In contrast, estimated Hgb were measured on seven automation systems: Abbott Alinity c, Roche cobas pro (n=2), Roche cobas 8000, Roche cobas 6000, Ortho Vitros 5600 (n=2), Siemens Atellica CH and Beckman Coulter AU680. Method comparison analyses were performed using Passing-Bablok linear regression. Bias was assessed at 50 mg/dL, the IFCC threshold for the hemolysis quality indicator. Subsequently, the percent bias for each automated application was calculated as [(automated Hgb - 50 mg/dL) / 50 mg/dL] x 100. Results All methods’ coefficient of variation (CV) of the hemolysis values for each sample revealed a close agreement among the automated analyzers with a combined CV of 24% and median CV of 8% (range 3% to 73%). However, the biases for Hgb estimates at the IFCC cut-off ranged from 1.4% to 23.0% across the entire range of Hgb levels (5 to 450 mg/dL). The specific biases observed when applying the linear regression for samples with Hgb concentrations <100 mg/dL were: 1.4-10.4% for Roche cobas analyzers, 20.2-21.4% for Ortho Vitros 5600 analyzers, 16.2% for Siemens Atellica CH, 8.0% for Abbott Alinity c and 18.2% for Beckman Coulter AU680, highlighting variations in Hgb estimates among automated analyzers. All automated analyzers demonstrated excellent correlation with the Khan method. The Pearson’s R values ranged from 0.997-0.999 for Hgb concentrations between 5-450 mg/dL, and 0.981-0.999 for Hgb concentrations <100 mg/dL. Conclusion In conclusion, our study revealed excellent correlation among automated analyzers in measuring hemolysis indices, supporting the reliability of these methods. Assessment of hemolysis at the sample level supports the IFCC harmonized quality indicator. However, notable positive biases were observed among some analyzers, which may impact comparisons of hemolysis rates, emphasizing the need for further harmonization among manufacturers.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.173
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-179 A Multi-Centre Assessment of Comparability of Hemolysis Indices on Automated Analyzers

Lusia Sepiashvili, Annie Ren, Bo Wan, Cristiana Stefan et al.
Clinical Chemistry
Heart Rate Variability and Autonomic Control
article

A-179 A Multi-Centre Assessment of Comparability of Hemolysis Indices on Automated Analyzers

Lusia Sepiashvili, Annie Ren, Bo Wan, Cristiana Stefan, Saranya Arnoldo, Davor Brinc, Meshach Asare-Werehene, Lei Fu, Paul S. F. Yip, Felix Leung, Mohamed Bhugun, Blaine Elliot, Nurun Muhammed
article en

Abstract

Abstract Background Hemolysis is a prevalent preanalytical issue that compromises quality and patient safety during laboratory testing. It can interfere with sample analysis, leading to inaccurate results, sample rejection, and delayed patient treatment. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has identified hemolysis as a high-priority quality indicator, defined as the rate of samples with hemoglobin (Hgb) above 50 mg/dL (>0.5 g/L). Automated methods have improved hemolysis detection in serum/plasma samples. However, the internal calibration of automated methods for hemoglobin estimation (i.e. Hemolysis index) is usually not verified for accuracy against external standards by the end-user nor standardized across methods. This study aims to address this gap by comparing hemoglobin quantification using the serum indices application on automated chemistry analyzers versus a conventional spectrophotometric method that is validated for plasma free hemoglobin measurement. Methods Plasma samples (n=20) were analyzed at nine laboratories across the Greater Toronto Area in Canada. The plasma free Hgb concentrations in patient samples ranging from 5 to 450 mg/dL (0.05 to 4.50 g/L) were determined with the method of Khan SE et al. (Ann Clin Lab Sci. 1981;11(2):126-31) on Agilent Cary 60 UV/Vis spectrophotometer as the reference. In contrast, estimated Hgb were measured on seven automation systems: Abbott Alinity c, Roche cobas pro (n=2), Roche cobas 8000, Roche cobas 6000, Ortho Vitros 5600 (n=2), Siemens Atellica CH and Beckman Coulter AU680. Method comparison analyses were performed using Passing-Bablok linear regression. Bias was assessed at 50 mg/dL, the IFCC threshold for the hemolysis quality indicator. Subsequently, the percent bias for each automated application was calculated as [(automated Hgb - 50 mg/dL) / 50 mg/dL] x 100. Results All methods’ coefficient of variation (CV) of the hemolysis values for each sample revealed a close agreement among the automated analyzers with a combined CV of 24% and median CV of 8% (range 3% to 73%). However, the biases for Hgb estimates at the IFCC cut-off ranged from 1.4% to 23.0% across the entire range of Hgb levels (5 to 450 mg/dL). The specific biases observed when applying the linear regression for samples with Hgb concentrations <100 mg/dL were: 1.4-10.4% for Roche cobas analyzers, 20.2-21.4% for Ortho Vitros 5600 analyzers, 16.2% for Siemens Atellica CH, 8.0% for Abbott Alinity c and 18.2% for Beckman Coulter AU680, highlighting variations in Hgb estimates among automated analyzers. All automated analyzers demonstrated excellent correlation with the Khan method. The Pearson’s R values ranged from 0.997-0.999 for Hgb concentrations between 5-450 mg/dL, and 0.981-0.999 for Hgb concentrations <100 mg/dL. Conclusion In conclusion, our study revealed excellent correlation among automated analyzers in measuring hemolysis indices, supporting the reliability of these methods. Assessment of hemolysis at the sample level supports the IFCC harmonized quality indicator. However, notable positive biases were observed among some analyzers, which may impact comparisons of hemolysis rates, emphasizing the need for further harmonization among manufacturers.

Clinical ChemistryVol. 71(Supplement_1)
Sunnybrook Health Science Centre (CA), University Health Network (CA), Centre for Addiction and Mental Health (CA), University of Toronto (CA), Hospital for Sick Children (CA), Brampton Civic Hospital (CA), Toronto East General Hospital (CA), Health Sciences Centre (CA), Markham Stouffville Hospital (CA), William Osler Health System (CA), Sinai Health System (CA), Compute Canada (CA)
Openalex Percentile: Top 59%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.