A-133 iSED PRO: Utilizing Photometric Rheology to Modernize High Throughput Erythrocyte Sedimentation Rate Testing

Abstract Background ESR is a non-specific lab test for assessing or monitoring patients with inflammatory conditions and one of the most common lab tests in the world. Traditional ESR testing is done via the manual Westergren method, but many laboratories have adopted automated ESR analyzers to improve workflow. iSED PRO is the latest analyzer in the iSED ESR analyzer family, specifically designed to maximize efficiency for high-throughput labs. Results are available within 20 seconds with <1 second of hands-on time per sample, significantly reducing time to result and improving patient care. Methods The iSED PRO technology utilizes photometric rheology to assess rouleaux formation, the first step of RBC sedimentation. The degree of RBC aggregation determines the degree of sedimentation. RBCs are pumped into the analyzer’s flow cell which disaggregates the cells. When the pump stops, an optical sensor detects the changes in light transmission through the sample as RBCs aggregate. iSED PRO calculates an ESR value based on light transmission. Results Method Correlation (iSED PRO vs Westergren, n=200) was performed according to CLSI Procedure H02-A5 and yielded a regression equation of y=1.03x+1.58, 95% CI of the slope is 1.000 to 1.093, and 95% CI of intercept is -0.058 to 2.000. CuSum test is >0.05, showing no deviation from linearity. Paired T-Test shows equivalence. Average intrarun precision results are 6.0% for samples 0-30 mm/hr, 2.9% for samples 31-60 mm/hr, 2.4% for samples 61-90 mm/hr, and 2.9% for samples >90 mm/hr. Average interrun precision is 4.3%. Average carryover is 1.83%. Conclusion The iSED PRO’s photometric rheology based ESR measurement correlates with the current ESR reference method, and its modern approach to ESR analysis optimizes laboratory efficiency while rapid reproducible results benefit the patients.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.129
Primary Topic
Blood properties and coagulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-133 iSED PRO: Utilizing Photometric Rheology to Modernize High Throughput Erythrocyte Sedimentation Rate Testing

Megan McCutcheon, Sandra Quaresmâ, Stephen Giarrusso, Joe Langella
Clinical Chemistry
Blood properties and coagulation
article

A-133 iSED PRO: Utilizing Photometric Rheology to Modernize High Throughput Erythrocyte Sedimentation Rate Testing

Megan McCutcheon, Sandra Quaresmâ, Stephen Giarrusso, Joe Langella
article en

Abstract

Abstract Background ESR is a non-specific lab test for assessing or monitoring patients with inflammatory conditions and one of the most common lab tests in the world. Traditional ESR testing is done via the manual Westergren method, but many laboratories have adopted automated ESR analyzers to improve workflow. iSED PRO is the latest analyzer in the iSED ESR analyzer family, specifically designed to maximize efficiency for high-throughput labs. Results are available within 20 seconds with <1 second of hands-on time per sample, significantly reducing time to result and improving patient care. Methods The iSED PRO technology utilizes photometric rheology to assess rouleaux formation, the first step of RBC sedimentation. The degree of RBC aggregation determines the degree of sedimentation. RBCs are pumped into the analyzer’s flow cell which disaggregates the cells. When the pump stops, an optical sensor detects the changes in light transmission through the sample as RBCs aggregate. iSED PRO calculates an ESR value based on light transmission. Results Method Correlation (iSED PRO vs Westergren, n=200) was performed according to CLSI Procedure H02-A5 and yielded a regression equation of y=1.03x+1.58, 95% CI of the slope is 1.000 to 1.093, and 95% CI of intercept is -0.058 to 2.000. CuSum test is >0.05, showing no deviation from linearity. Paired T-Test shows equivalence. Average intrarun precision results are 6.0% for samples 0-30 mm/hr, 2.9% for samples 31-60 mm/hr, 2.4% for samples 61-90 mm/hr, and 2.9% for samples >90 mm/hr. Average interrun precision is 4.3%. Average carryover is 1.83%. Conclusion The iSED PRO’s photometric rheology based ESR measurement correlates with the current ESR reference method, and its modern approach to ESR analysis optimizes laboratory efficiency while rapid reproducible results benefit the patients.

Clinical ChemistryVol. 71(Supplement_1)
Rhode Island Department of Health (US), Bryant University (US), Electro Standards Laboratories (United States) (US)
Openalex Percentile: Top 60%
Blood properties and coagulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.