A-116 Mixing it up: Salvaging frozen specimens

Abstract Background Proper specimen collection is necessary to minimize pre-analytical errors. Analyte stability after freezing is often provided with FDA approvals but is done on an aliquot instead of in the specimen collection container. The aim of this study is to examine the effect of freezing due to improper storage and/or transport on serum and plasma analytes from centrifuged and gel-separated samples. We investigate whether mixing thawed specimens can salvage the sample, preventing unnecessary patient re-draws and reducing laboratory costs. Methods Thirty fresh plasma and serum specimens that were not required for clinical care were randomly chosen. Baseline values for TSH, vitamin B12, vitamin D3, total PSA and Comprehensive Metabolic Panel (CMP) were collected. Specimens were frozen at -20? C for 24 hours, mimicking the winter conditions in outpatient pickup boxes. Specimens were then thawed at room temperature for 90-120 minutes and re-tested. Then, they were recapped and gently mixed for 10 minutes and re-tested a third time. CLIA, CAP and RCPA total allowable error (TAE) guidelines were utilized to assess whether or not a significant change occurred, in at least one sample, between the baseline and mixed values. Additionally, the data were analyzed using both male and female reference intervals to see if the clinical interpretations changed significantly within our laboratory (>10% of samples affected). Results Both serum and plasma specimens were affected significantly when assessed by either TAE and/or reference range standards. For the frozen, non-mixed plasma samples, the majority of the analytes (14/18, 78%)—except TPSA, Vitamin B12, TSH, and Alkaline Phosphatase—were outside TAE standards. However, upon mixing, eight of these analytes corrected themselves, leaving only six analytes (Potassium, Glucose, Total Bilirubin, Bicarbonate, AST and ALT) in the out-of-range category. Three analytes (AST, Bicarbonate, and Potassium, 18%) were altered when using the female reference intervals. Whereas when using the male reference intervals, Bicarbonate, Potassium, and TPSA had alterations in interpretation (17%). Regarding the serum samples, all of the analytes in the frozen, non-mixed specimens (18/18, 100%) were out of range per TAE standards. After mixing, only eight of the analytes (8/18, 44%) had fallen back within range. Regarding a change in clinical interpretation, five analytes (Bicarbonate, Chloride, Potassium, Sodium, and Vitamin D, 29%) were altered when using the female reference intervals, whereas when using the male values, a total of 6 analytes (aforementioned plus Creatinine, 33% of specimens) had changes in interpretation. Conclusion Real-world conditions may create pre-analytical errors that impact analyte results and must be considered. Importantly, this study showed that despite an analyte being stable per the FDA approval on an aliquot, this was not always the case in the specimen collection container. Plasma samples were generally more stable than serum samples, but both had clinically significant changes. These findings have the potential to impact patient care significantly and suggest that manufacturers should be required to provide freeze-thaw stability in approved specimen containers.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.114
Primary Topic
Cryospheric studies and observations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-116 Mixing it up: Salvaging frozen specimens

Robert C. Benirschke, Hong-Kee Lee, Nicholas D. Evans, Ximena Wise et al.
Clinical Chemistry
Cryospheric studies and observations
article

A-116 Mixing it up: Salvaging frozen specimens

Robert C. Benirschke, Hong-Kee Lee, Nicholas D. Evans, Ximena Wise, Clovis Sarmiento
article en

Abstract

Abstract Background Proper specimen collection is necessary to minimize pre-analytical errors. Analyte stability after freezing is often provided with FDA approvals but is done on an aliquot instead of in the specimen collection container. The aim of this study is to examine the effect of freezing due to improper storage and/or transport on serum and plasma analytes from centrifuged and gel-separated samples. We investigate whether mixing thawed specimens can salvage the sample, preventing unnecessary patient re-draws and reducing laboratory costs. Methods Thirty fresh plasma and serum specimens that were not required for clinical care were randomly chosen. Baseline values for TSH, vitamin B12, vitamin D3, total PSA and Comprehensive Metabolic Panel (CMP) were collected. Specimens were frozen at -20? C for 24 hours, mimicking the winter conditions in outpatient pickup boxes. Specimens were then thawed at room temperature for 90-120 minutes and re-tested. Then, they were recapped and gently mixed for 10 minutes and re-tested a third time. CLIA, CAP and RCPA total allowable error (TAE) guidelines were utilized to assess whether or not a significant change occurred, in at least one sample, between the baseline and mixed values. Additionally, the data were analyzed using both male and female reference intervals to see if the clinical interpretations changed significantly within our laboratory (>10% of samples affected). Results Both serum and plasma specimens were affected significantly when assessed by either TAE and/or reference range standards. For the frozen, non-mixed plasma samples, the majority of the analytes (14/18, 78%)—except TPSA, Vitamin B12, TSH, and Alkaline Phosphatase—were outside TAE standards. However, upon mixing, eight of these analytes corrected themselves, leaving only six analytes (Potassium, Glucose, Total Bilirubin, Bicarbonate, AST and ALT) in the out-of-range category. Three analytes (AST, Bicarbonate, and Potassium, 18%) were altered when using the female reference intervals. Whereas when using the male reference intervals, Bicarbonate, Potassium, and TPSA had alterations in interpretation (17%). Regarding the serum samples, all of the analytes in the frozen, non-mixed specimens (18/18, 100%) were out of range per TAE standards. After mixing, only eight of the analytes (8/18, 44%) had fallen back within range. Regarding a change in clinical interpretation, five analytes (Bicarbonate, Chloride, Potassium, Sodium, and Vitamin D, 29%) were altered when using the female reference intervals, whereas when using the male values, a total of 6 analytes (aforementioned plus Creatinine, 33% of specimens) had changes in interpretation. Conclusion Real-world conditions may create pre-analytical errors that impact analyte results and must be considered. Importantly, this study showed that despite an analyte being stable per the FDA approval on an aliquot, this was not always the case in the specimen collection container. Plasma samples were generally more stable than serum samples, but both had clinically significant changes. These findings have the potential to impact patient care significantly and suggest that manufacturers should be required to provide freeze-thaw stability in approved specimen containers.

Clinical ChemistryVol. 71(Supplement_1)
NorthShore University HealthSystem (US), University of Chicago (US)
Openalex Percentile: Top 68%
Cryospheric studies and observations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.