A-169 Mean reticulocyte volume reported by Mindray 6800 Plus for the diagnosis of iron restricted erythropoiesis

Abstract Background The Mindray BC 6800+ counter, using a new software version, can report mean reticulocyte volume (MRV); we study its values in anemia of different underlying causes and the reliability for the diagnosis of iron deficient erythropoiesis. Methods 606 samples collected in K2EDTA anti-coagulant were analyzed. The scope of the pathology included a variety of diseases representative of the daily workload: 105 healthy subjects, 55 non-anemic patients, 202 microcytic anemia (including thalassemia carriers and iron deficiency anemia), 215 normocytic anemia (hematology malignancies and anemia of chronic disease) , 84 macrocytic anemia (lack of vitamin B12 or folate and myelodysplasic syndromes (MDS). C reactive protein (CRP), S-iron, transferrin saturation,s- ferritin and soluble transferrin receptor (sTfR) were assayed assayed in a analyzer Cobas c 502 (Roche Diagnostics) analyzer . Kolmogorov-Smirnoff was used to verify normal distribution of data. Differences among groups were assessed using analysis of variance, considering P < 0.05 to be significant. For post hoc comparisons of outcomes between each pair of groups Scheffé correction was applied. Receiver operating characteristic analysis was used to assess the diagnostic performance of MRV for detecting iron deficient erythropoiesis. Gold standard for iron deficiency was sTfR >52 nmol/L. Results Gaussian distribution was proven. Whole MRV range 51.8-151.3 fL Mean and range in healthy subjects 107.8 fL, 94.6-121.2 fL Microcytic anemia mean 78.5 fL standard deviation (SD) 13.5 fL Normocytic anemia Mean 105.1 fL, SD 16.9 fL Macrocytic anemia Mean 122.5 fL, SD 18.6 fL In the microcytic group, the values in patients with IDA (MRV mean 78.8 fL, SD 14.3 fL) and thalassemia carries (MRV mean 76.6 fL, SD 10.2 fL) were not significantly different P=0.0756. So patients with restricted erythropoiesis, due to lack of iron or globin, had similar low values. Values over the reference range in the macrocytic group is not related to iron status, reflects the megaloblastosis. Based on Hemoglobin (Hb), Mean cell volume (MCV) , CRP, ferritin and sTfR values the patients were classified as , iron deficiency (IDA ), anemia of chronic disease (ACD) under therapy, and mixed anemia (ACD with iron deficiency, ACD/IDA) , or latent iron deficiency (LID). MVR values were: IDA 78.8 fL , SD 14.3 fL; ACD /IDA 90.5 fL , SD 17.8 fL; ACD 97.7 fL , SD 18.8 fL LID 88.4 fL , SD 16.9 fL. The groups had MRV values significantly different P=0.0001, except the healthy group and ACD with adequate iron supply patients, P=0.0754, IDA and LID groups P=0.0809. Using a cut off MRV 94.6 fL, iron deficient erythropoiesis could be diagnosed sensitivity 82.9%, specificity 97.6%. Area under the curve was 0.929 (95% CI 0.889–0.949) Conclusions Disturbances in erythropoiesis and iron metabolism may occur in many patients, the challenge is to identify these patients as early as possible. MRV provides a sensitive method for quantifying the haemoglobinization of reticulocytes. It is a reliable marker to identify iron deficient erythropoiesis, MRV may allow the complete scope of disorders of iron metabolism to be identified quickly and managed.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.164
Citations
1
Primary Topic
Hemoglobinopathies and Related Disorders
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-169 Mean reticulocyte volume reported by Mindray 6800 Plus for the diagnosis of iron restricted erythropoiesis

Eloísa Urrechaga, Monica Fermnandez
1 citations
Clinical Chemistry
Hemoglobinopathies and Related Disorders
1.63
article

A-169 Mean reticulocyte volume reported by Mindray 6800 Plus for the diagnosis of iron restricted erythropoiesis

Eloísa Urrechaga, Monica Fermnandez
article en
1 citations

Abstract

Abstract Background The Mindray BC 6800+ counter, using a new software version, can report mean reticulocyte volume (MRV); we study its values in anemia of different underlying causes and the reliability for the diagnosis of iron deficient erythropoiesis. Methods 606 samples collected in K2EDTA anti-coagulant were analyzed. The scope of the pathology included a variety of diseases representative of the daily workload: 105 healthy subjects, 55 non-anemic patients, 202 microcytic anemia (including thalassemia carriers and iron deficiency anemia), 215 normocytic anemia (hematology malignancies and anemia of chronic disease) , 84 macrocytic anemia (lack of vitamin B12 or folate and myelodysplasic syndromes (MDS). C reactive protein (CRP), S-iron, transferrin saturation,s- ferritin and soluble transferrin receptor (sTfR) were assayed assayed in a analyzer Cobas c 502 (Roche Diagnostics) analyzer . Kolmogorov-Smirnoff was used to verify normal distribution of data. Differences among groups were assessed using analysis of variance, considering P < 0.05 to be significant. For post hoc comparisons of outcomes between each pair of groups Scheffé correction was applied. Receiver operating characteristic analysis was used to assess the diagnostic performance of MRV for detecting iron deficient erythropoiesis. Gold standard for iron deficiency was sTfR >52 nmol/L. Results Gaussian distribution was proven. Whole MRV range 51.8-151.3 fL Mean and range in healthy subjects 107.8 fL, 94.6-121.2 fL Microcytic anemia mean 78.5 fL standard deviation (SD) 13.5 fL Normocytic anemia Mean 105.1 fL, SD 16.9 fL Macrocytic anemia Mean 122.5 fL, SD 18.6 fL In the microcytic group, the values in patients with IDA (MRV mean 78.8 fL, SD 14.3 fL) and thalassemia carries (MRV mean 76.6 fL, SD 10.2 fL) were not significantly different P=0.0756. So patients with restricted erythropoiesis, due to lack of iron or globin, had similar low values. Values over the reference range in the macrocytic group is not related to iron status, reflects the megaloblastosis. Based on Hemoglobin (Hb), Mean cell volume (MCV) , CRP, ferritin and sTfR values the patients were classified as , iron deficiency (IDA ), anemia of chronic disease (ACD) under therapy, and mixed anemia (ACD with iron deficiency, ACD/IDA) , or latent iron deficiency (LID). MVR values were: IDA 78.8 fL , SD 14.3 fL; ACD /IDA 90.5 fL , SD 17.8 fL; ACD 97.7 fL , SD 18.8 fL LID 88.4 fL , SD 16.9 fL. The groups had MRV values significantly different P=0.0001, except the healthy group and ACD with adequate iron supply patients, P=0.0754, IDA and LID groups P=0.0809. Using a cut off MRV 94.6 fL, iron deficient erythropoiesis could be diagnosed sensitivity 82.9%, specificity 97.6%. Area under the curve was 0.929 (95% CI 0.889–0.949) Conclusions Disturbances in erythropoiesis and iron metabolism may occur in many patients, the challenge is to identify these patients as early as possible. MRV provides a sensitive method for quantifying the haemoglobinization of reticulocytes. It is a reliable marker to identify iron deficient erythropoiesis, MRV may allow the complete scope of disorders of iron metabolism to be identified quickly and managed.

Clinical ChemistryVol. 71(Supplement_1)
Hospital de Galdakao (ES), Osakidetza (ES)
Openalex Percentile: Top 13%
Hemoglobinopathies and Related Disorders
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.