A-085 Clinical Consequences of lack of Standardization/Harmonization of Ferritin Assays

Abstract Background The lack of standardization and harmonization among ferritin assays results in significant variability in clinical values. These assays have different reference ranges and numerous clinical cut-offs for interpreting anemia and iron toxicity. This inconsistency is due to manufacturers using various calibrators. Such variability complicates the interpretation and comparison of results across different clinical settings. Methods Ferritin was ordered for 7815 patient samples in 3 months and assays were performed by DXI. Similarly, 5818 patients’ samples were run by Roche in two months. Both assays are FDA cleared and are commonly used by hundreds of clinical laboratories. Frequency of no of patients flagged low or flagged were calculated with respective reference ranges of Dxi and Cobas. Results 12 percent of the patients were flagged low by the Beckman assay and would have gotten both physician and patients attention. However, by the Roche assay only 4 percent were flagged low. This was alarming to our physicians and lab was told to investigate to find for this shift. Manufacturer/Time Range Total Volume Total High Total Low %High %Low Dxi-May-24 2617 368 326 14.1% 12% Dxi-Jun-24 2391 345 278 14% 12% Dxi-Jul-24 2807 500 308 17.8% 11% Cobas-801 August 2024 - Ferritin Go Live Cobas-801-Sep-24 2545 572 105 22% 4% Cobas-801-Oct-24 2841 695 121 24% 4% Conclusion Lack of Standardization and harmonization has serious consequences for the patients being tested for ferritin to diagnose deficiency of iron or high iron situations. We are planning to do a prospective study to determine clinical cut-offs by correlating Ferritin lab results with other gold standard biomarkers including bone marrow biopsy.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.084
Primary Topic
Iron Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-085 Clinical Consequences of lack of Standardization/Harmonization of Ferritin Assays

Ravinder Singh, Teffany Reaves
Clinical Chemistry
Iron Metabolism and Disorders
article

A-085 Clinical Consequences of lack of Standardization/Harmonization of Ferritin Assays

Ravinder Singh, Teffany Reaves
article en

Abstract

Abstract Background The lack of standardization and harmonization among ferritin assays results in significant variability in clinical values. These assays have different reference ranges and numerous clinical cut-offs for interpreting anemia and iron toxicity. This inconsistency is due to manufacturers using various calibrators. Such variability complicates the interpretation and comparison of results across different clinical settings. Methods Ferritin was ordered for 7815 patient samples in 3 months and assays were performed by DXI. Similarly, 5818 patients’ samples were run by Roche in two months. Both assays are FDA cleared and are commonly used by hundreds of clinical laboratories. Frequency of no of patients flagged low or flagged were calculated with respective reference ranges of Dxi and Cobas. Results 12 percent of the patients were flagged low by the Beckman assay and would have gotten both physician and patients attention. However, by the Roche assay only 4 percent were flagged low. This was alarming to our physicians and lab was told to investigate to find for this shift. Manufacturer/Time Range Total Volume Total High Total Low %High %Low Dxi-May-24 2617 368 326 14.1% 12% Dxi-Jun-24 2391 345 278 14% 12% Dxi-Jul-24 2807 500 308 17.8% 11% Cobas-801 August 2024 - Ferritin Go Live Cobas-801-Sep-24 2545 572 105 22% 4% Cobas-801-Oct-24 2841 695 121 24% 4% Conclusion Lack of Standardization and harmonization has serious consequences for the patients being tested for ferritin to diagnose deficiency of iron or high iron situations. We are planning to do a prospective study to determine clinical cut-offs by correlating Ferritin lab results with other gold standard biomarkers including bone marrow biopsy.

Clinical ChemistryVol. 71(Supplement_1)
Mayo Clinic (US), Jacksonville College (US)
Openalex Percentile: Top 65%
Iron Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A-085 Clinical Consequences of lack of Standardization/Harmonization of Ferritin Assays — Ravinder Singh, Teffany Reaves · Clinical Chemistry (2025) | TGRS Research Map | TGRS