A-295 A Multicenter Evaluation of the Access Syphilis Assay on the DxI 9000 and Access 2 Immunoassay Analyzers

Abstract Background Beckman Coulter, Inc. has developed a fully automated Access Syphilis assay* for use on the DxI 9000 and Access 2 Immunoassay Analyzers. This assay can report results in =40 minutes using a serum or plasma sample volume of just 50 µL or less with no duplicate retesting. This study aims to evaluate the analytical and clinical performance of this assay. Methods Imprecision and reproducibility studies were conducted in accordance with CLSI EP05-A3 on both DxI 9000 and Access 2 analyzers. Imprecision was evaluated in a 20-day, 2 runs/day, 2 replicates/run study on serum and plasma samples with three reagent lots. Reproducibility was evaluated at 3 US clinical laboratories with serum and quality control samples (n=360 reps per sample) on three reagent lots. Cross-reactivity was evaluated using 337 specimens from 35 potential cross-reactant categories from individuals with conditions unrelated to syphilis infection (e.g., infections, auto-immunity, rheumatoid factor). The clinical performance on the DxI 9000 and Access 2 analyzers was evaluated at three U.S clinical laboratories. The performance of the Access Syphilis assay was compared to a final comparator result obtained using a composite algorithm of results from commercially available syphilis assays: the Abbott Architect Syphilis TP assay, a non-treponemal assay (Becton Dickenson Macro-Vue Rapid Plasma Reagin [RPR] Card), and a second treponemal assay (Fujirebio Inc. Serodia Treponema pallidum Particle Agglutination [TP-PA]). Results For positive samples, imprecision of < 9% and <8% and reproducibility of <6% and <9% on Access 2 and DxI 9000, respectively, were observed. For negative samples, imprecision of <0.041 and <0.075 SD and reproducibility of <0.035 and <0.052 SD on Access 2 and DxI 9000, respectively, were observed. No cross-reactivity was observed on either platform for any sample/condition. The clinical study results demonstrated a positive percent agreement (PPA) of 100% for the Access Syphilis assay (n=184; 95% CI: 98-100%) and a negative percent agreement (NPA) of 96.7% (n=920; 95% CI: 95.4-97.7%) in the intended use population on both platforms. Conclusion The newly developed Access Syphilis assay for the DxI 9000 and Access 2 Immunoassay Analyzers has shown excellent analytical and clinical performance consistent with currently marketed syphilis assays. *FDA cleared in the US, not yet available for in vitro diagnostic use in all countries IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.284
Primary Topic
Syphilis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-295 A Multicenter Evaluation of the Access Syphilis Assay on the DxI 9000 and Access 2 Immunoassay Analyzers

Danielle Maher, Karen Schulz, Yann Ciczora, Robert H. Christenson et al.
Clinical Chemistry
Syphilis Diagnosis and Treatment
article

A-295 A Multicenter Evaluation of the Access Syphilis Assay on the DxI 9000 and Access 2 Immunoassay Analyzers

Danielle Maher, Karen Schulz, Yann Ciczora, Robert H. Christenson, Saeed A. Jortani, Fred S. Apple, Bridget Mathison, Eric Rouvier, Clara Milhem
article en

Abstract

Abstract Background Beckman Coulter, Inc. has developed a fully automated Access Syphilis assay* for use on the DxI 9000 and Access 2 Immunoassay Analyzers. This assay can report results in =40 minutes using a serum or plasma sample volume of just 50 µL or less with no duplicate retesting. This study aims to evaluate the analytical and clinical performance of this assay. Methods Imprecision and reproducibility studies were conducted in accordance with CLSI EP05-A3 on both DxI 9000 and Access 2 analyzers. Imprecision was evaluated in a 20-day, 2 runs/day, 2 replicates/run study on serum and plasma samples with three reagent lots. Reproducibility was evaluated at 3 US clinical laboratories with serum and quality control samples (n=360 reps per sample) on three reagent lots. Cross-reactivity was evaluated using 337 specimens from 35 potential cross-reactant categories from individuals with conditions unrelated to syphilis infection (e.g., infections, auto-immunity, rheumatoid factor). The clinical performance on the DxI 9000 and Access 2 analyzers was evaluated at three U.S clinical laboratories. The performance of the Access Syphilis assay was compared to a final comparator result obtained using a composite algorithm of results from commercially available syphilis assays: the Abbott Architect Syphilis TP assay, a non-treponemal assay (Becton Dickenson Macro-Vue Rapid Plasma Reagin [RPR] Card), and a second treponemal assay (Fujirebio Inc. Serodia Treponema pallidum Particle Agglutination [TP-PA]). Results For positive samples, imprecision of < 9% and <8% and reproducibility of <6% and <9% on Access 2 and DxI 9000, respectively, were observed. For negative samples, imprecision of <0.041 and <0.075 SD and reproducibility of <0.035 and <0.052 SD on Access 2 and DxI 9000, respectively, were observed. No cross-reactivity was observed on either platform for any sample/condition. The clinical study results demonstrated a positive percent agreement (PPA) of 100% for the Access Syphilis assay (n=184; 95% CI: 98-100%) and a negative percent agreement (NPA) of 96.7% (n=920; 95% CI: 95.4-97.7%) in the intended use population on both platforms. Conclusion The newly developed Access Syphilis assay for the DxI 9000 and Access 2 Immunoassay Analyzers has shown excellent analytical and clinical performance consistent with currently marketed syphilis assays. *FDA cleared in the US, not yet available for in vitro diagnostic use in all countries IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."

Clinical ChemistryVol. 71(Supplement_1)
University of Maryland, Baltimore (US), Bio-Rad (United States) (US), Hennepin County Medical Center (US), Bio-Rad (France) (FR), Advanced Genomic Technology (United States) (US), Beckman Coulter Foundation (US), Hennepin Healthcare Research Institute (US)
Openalex Percentile: Top 66%
Syphilis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.