A-376 Performance of Viscoelastic testing on the ROTEM sigma

Abstract Background Our laboratory was asked to perform Viscoelastic testing on the Rotem Sigma (Point of Care) (Werfen, Munich, Germany), currently performed by the Anesthesia Department on the Rotem Delta (Benchtop) analyzer to support liver transplantation surgery. This testing, performed on citrated whole blood, supports transfusion management and optimization of hemostasis. The semi-quantitative assays performed on each test cartridge consist of INTEM C (to monitor coagulation via the intrinsic pathway), EXTEM C (to monitor coagulation via the extrinsic pathway), FIBTEM C (to monitor coagulation via the extrinsic pathway, assessing fibrinogen status and fibrin polymerization by blocking platelet contribution to clot firmness), and HEPTEM C (to monitor coagulation via the intrinsic pathway, after inactivating heparin). Each assay provides several parameters including Clotting Time (CT), Amplitude (up to 20 minutes after clotting time), Maximum Clot Formation (MCF), and Lysis Index after 60 minutes (LI60). We also evaluated the impact on specimens during transportation through the pneumatic tube. Methods Precision studies were performed using Quality Control materials ROTROL N and P (Werfen, Munich, Germany). Comparison studies were performed on citrated whole blood against the Rotem Delta (Werfen, Munich, Germany), and between citrated whole blood samples that were carried by hand versus being sent to the lab by pneumatic tube. Results Precision studies for Rotem Sigma (n=38) for ROTROL N and P, respectively, were: EXTEM C-(Amplitude, shown as a range) 5.6%-6.8% and 3.2-4.2%; EXTEM C-CT 9.2% and 5.4%; FIBTEM C-(Amplitude, shown as a range) 4.4%-5.1% and 5.1%-6.7%; HEPTEM C-(Amplitude, shown as a range) 5.7%-7.4% and 4.3%-8.3%; HEPTEM C-CT 9.5% and 6.6%; INTEM C-(Amplitude, shown as a range) 2.0-2.4% and 2.9%- 3.2%; INTEM C-CT 4.2% and 3.3. Method Comparison results were EXTEM C-(Amplitude, shown as a range) R=0.7607-0.7667; EXTEM C-CT R=0.7090; EXTEM C-MCF R=0.7026; FIBTEM C-(Amplitude, shown as a range) R=0.9160-0.9290; FIBTEM C-MCF R=0.9265; HEPTEM C-(Amplitude, shown as a range) R=0.8525-0.8751; HEPTEM C-CT R=0.7719; HEPTEM C-MCF R=0.8343 (Table 1). Comparison of hand-carried specimens to those sent by pneumatic tube demonstrated a maximum difference of <|8.0|% for all assays and parameters. Conclusion The Rotem Sigma showed good precision and acceptable correlation to the Rotem Delta and is considered acceptable for testing patient samples. In addition, the pneumatic tube has been shown to be an acceptable means of transportation for samples intended to be tested on the Rotem Sigma.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1093/clinchem/hvaf086.360
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A-376 Performance of Viscoelastic testing on the ROTEM sigma

Lilah Evans, Barbara Goldsmith
Clinical Chemistry
Superconducting Materials and Applications
article

A-376 Performance of Viscoelastic testing on the ROTEM sigma

Lilah Evans, Barbara Goldsmith
article en

Abstract

Abstract Background Our laboratory was asked to perform Viscoelastic testing on the Rotem Sigma (Point of Care) (Werfen, Munich, Germany), currently performed by the Anesthesia Department on the Rotem Delta (Benchtop) analyzer to support liver transplantation surgery. This testing, performed on citrated whole blood, supports transfusion management and optimization of hemostasis. The semi-quantitative assays performed on each test cartridge consist of INTEM C (to monitor coagulation via the intrinsic pathway), EXTEM C (to monitor coagulation via the extrinsic pathway), FIBTEM C (to monitor coagulation via the extrinsic pathway, assessing fibrinogen status and fibrin polymerization by blocking platelet contribution to clot firmness), and HEPTEM C (to monitor coagulation via the intrinsic pathway, after inactivating heparin). Each assay provides several parameters including Clotting Time (CT), Amplitude (up to 20 minutes after clotting time), Maximum Clot Formation (MCF), and Lysis Index after 60 minutes (LI60). We also evaluated the impact on specimens during transportation through the pneumatic tube. Methods Precision studies were performed using Quality Control materials ROTROL N and P (Werfen, Munich, Germany). Comparison studies were performed on citrated whole blood against the Rotem Delta (Werfen, Munich, Germany), and between citrated whole blood samples that were carried by hand versus being sent to the lab by pneumatic tube. Results Precision studies for Rotem Sigma (n=38) for ROTROL N and P, respectively, were: EXTEM C-(Amplitude, shown as a range) 5.6%-6.8% and 3.2-4.2%; EXTEM C-CT 9.2% and 5.4%; FIBTEM C-(Amplitude, shown as a range) 4.4%-5.1% and 5.1%-6.7%; HEPTEM C-(Amplitude, shown as a range) 5.7%-7.4% and 4.3%-8.3%; HEPTEM C-CT 9.5% and 6.6%; INTEM C-(Amplitude, shown as a range) 2.0-2.4% and 2.9%- 3.2%; INTEM C-CT 4.2% and 3.3. Method Comparison results were EXTEM C-(Amplitude, shown as a range) R=0.7607-0.7667; EXTEM C-CT R=0.7090; EXTEM C-MCF R=0.7026; FIBTEM C-(Amplitude, shown as a range) R=0.9160-0.9290; FIBTEM C-MCF R=0.9265; HEPTEM C-(Amplitude, shown as a range) R=0.8525-0.8751; HEPTEM C-CT R=0.7719; HEPTEM C-MCF R=0.8343 (Table 1). Comparison of hand-carried specimens to those sent by pneumatic tube demonstrated a maximum difference of <|8.0|% for all assays and parameters. Conclusion The Rotem Sigma showed good precision and acceptable correlation to the Rotem Delta and is considered acceptable for testing patient samples. In addition, the pneumatic tube has been shown to be an acceptable means of transportation for samples intended to be tested on the Rotem Sigma.

Clinical ChemistryVol. 71(Supplement_1)
Thomas Jefferson University Hospital (US)
Openalex Percentile: Top 74%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.