Integrated and turnkey custom-built multiplexed portable platform for on-site electrochemical detection

A compact and cost-effective device is essential to bring multiplexed biosensing from lab to the point-of-care. Electrochemical sensing has emerged as a powerful choice for developing such lab-on-chip (LOC) platforms, offering good sensitivity, scalability, and compatibility. A potentiostat is a fundamental instrument widely employed in electrochemical sensors for clinical diagnostics, environmental monitoring, immunosensors, toxicity testing, and so on. However, conventional electrochemical workstations are often bulky and expensive, limiting their feasibility for portable, cost-effective biosensing, particularly for multiplexed detection at the point of care. Hence, it is ill-suited for the integration with lab-on-chip systems. This paper presents a low-cost, portable potentiostat with multiplexed electrochemical biosensing capability and Wi-Fi connectivity designated as μBIOPOT. This operates within a potential window of ±1 V and a current range of ±1 mA, supporting various voltammetric techniques, including Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Differential Pulse Voltammetry (DPV), Square Wave Voltammetry (SWV), and Normal Pulse Voltammetry (NPV). Its multiplexed capability enables real-time detection of multiple analytes, addressing key challenges in rapid and comprehensive biosensing. Validation of performance is done using the redox probe ferri/ferrocyanide, with results demonstrating close alignment with those obtained with a commercially available conventional potentiostat. Additionally, the device is tested for its ability to detect two key lipid biomarkers-cholesterol and triglycerides, demonstrating its ability for multiplexed detection. User-friendly interfaces provide real-time characteristic plots for research and simplified options for non-experts to determine biomarker concentrations. With Wi-Fi connectivity, low power consumption, and affordability at just $36, μBIOPOT represents a scalable, accessible, and efficient solution for the development of multiplexed electrochemical biosensors in both clinical and resource-limited settings.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2025-01-01
DOI
https://doi.org/10.1039/d5lc00732a
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated and turnkey custom-built multiplexed portable platform for on-site electrochemical detection

Sanket Goel, R. N. Ponnalagu, Souvik Roy, Kishori Sharan et al.
Lab on a Chip
Advanced Chemical Sensor Technologies
article

Integrated and turnkey custom-built multiplexed portable platform for on-site electrochemical detection

Sanket Goel, R. N. Ponnalagu, Souvik Roy, Kishori Sharan, Parvathy Nair, Aditya Balasubramanian
article en

Abstract

A compact and cost-effective device is essential to bring multiplexed biosensing from lab to the point-of-care. Electrochemical sensing has emerged as a powerful choice for developing such lab-on-chip (LOC) platforms, offering good sensitivity, scalability, and compatibility. A potentiostat is a fundamental instrument widely employed in electrochemical sensors for clinical diagnostics, environmental monitoring, immunosensors, toxicity testing, and so on. However, conventional electrochemical workstations are often bulky and expensive, limiting their feasibility for portable, cost-effective biosensing, particularly for multiplexed detection at the point of care. Hence, it is ill-suited for the integration with lab-on-chip systems. This paper presents a low-cost, portable potentiostat with multiplexed electrochemical biosensing capability and Wi-Fi connectivity designated as μBIOPOT. This operates within a potential window of ±1 V and a current range of ±1 mA, supporting various voltammetric techniques, including Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Differential Pulse Voltammetry (DPV), Square Wave Voltammetry (SWV), and Normal Pulse Voltammetry (NPV). Its multiplexed capability enables real-time detection of multiple analytes, addressing key challenges in rapid and comprehensive biosensing. Validation of performance is done using the redox probe ferri/ferrocyanide, with results demonstrating close alignment with those obtained with a commercially available conventional potentiostat. Additionally, the device is tested for its ability to detect two key lipid biomarkers-cholesterol and triglycerides, demonstrating its ability for multiplexed detection. User-friendly interfaces provide real-time characteristic plots for research and simplified options for non-experts to determine biomarker concentrations. With Wi-Fi connectivity, low power consumption, and affordability at just $36, μBIOPOT represents a scalable, accessible, and efficient solution for the development of multiplexed electrochemical biosensors in both clinical and resource-limited settings.

Lab on a ChipVol. 25(22)
Birla Institute of Technology and Science - Hyderabad Campus (IN)
Openalex Percentile: Top 74%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.