Calculation of sphere centers based on point cloud data from a Metrological Laser Radar

The increasing demands for 3D measurement accuracy in industrial metrology and quality control highlight the performance evaluation of Metrological Laser Radars (MLRs). The fitting calculation of sphere centers plays an important role in the relative range test of MLRs. This paper addresses this challenge by investigating the 3D point could data of a sphere by a MLR. In the experiment, the sphere is scanned at seven positions to analyze the influence of cone angles on the Root Mean Square (RMS) of sphere center fitting based on the cone-cylinder method given in the ASTM E57 standard. The results validate the applicability of the ASTM E57 standard for evaluating the accuracy of MLRs, and indicate that the laser incidence angle of the MLR may have a small impact on the RMS of the point cloud of the standard sphere surface.

Authors

Institutions

Publication Details

Journal
MATEC Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/matecconf/202541301012
Primary Topic
3D Surveying and Cultural Heritage
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation of sphere centers based on point cloud data from a Metrological Laser Radar

Anbin Sun, Jihu Wang, Ling Wang, Jingjing Fan et al.
MATEC Web of Conferences
3D Surveying and Cultural Heritage
article

Calculation of sphere centers based on point cloud data from a Metrological Laser Radar

Anbin Sun, Jihu Wang, Ling Wang, Jingjing Fan, W. Qian, Binrui Wang
article en

Abstract

The increasing demands for 3D measurement accuracy in industrial metrology and quality control highlight the performance evaluation of Metrological Laser Radars (MLRs). The fitting calculation of sphere centers plays an important role in the relative range test of MLRs. This paper addresses this challenge by investigating the 3D point could data of a sphere by a MLR. In the experiment, the sphere is scanned at seven positions to analyze the influence of cone angles on the Root Mean Square (RMS) of sphere center fitting based on the cone-cylinder method given in the ASTM E57 standard. The results validate the applicability of the ASTM E57 standard for evaluating the accuracy of MLRs, and indicate that the laser incidence angle of the MLR may have a small impact on the RMS of the point cloud of the standard sphere surface.

MATEC Web of ConferencesVol. 413
Beijing Zhenxing Metrology & Measurement Institute (CN), China Jiliang University (CN)
Openalex Percentile: Top 63%
3D Surveying and Cultural Heritage
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.