Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

The magnetic gradient tensor measurement system (MGTMS) is critical for detecting and localizing ferromagnetic targets. However, its localization accuracy is closely linked to measurement precision, which is often compromised by sensor misalignment errors. To mitigate these errors, this study proposes a practical calibration method using a standard magnetic source, achieving effective misalignment correction with minimal system alteration. The proposed method is validated through both simulations and localization experiments. Simulation results indicate that the root mean square error (RMSE) of the calibrated tensor values is reduced by three orders of magnitude compared to the uncalibrated state. Experimental results further demonstrate that the average localization error decreases from 0.040 m to 0.019 m after calibration, corresponding to a 52.5% improvement in positioning accuracy. These results highlight the potential of improving the accuracy of MGTMS-based target localization in practical applications.

Authors

Institutions

Publication Details

Journal
MATEC Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/matecconf/202541301009
Primary Topic
Geophysics and Gravity Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

Yingzi Zhang, Qingping Yang, Yali Shen
MATEC Web of Conferences
Geophysics and Gravity Measurements
article

Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

Yingzi Zhang, Qingping Yang, Yali Shen
article en

Abstract

The magnetic gradient tensor measurement system (MGTMS) is critical for detecting and localizing ferromagnetic targets. However, its localization accuracy is closely linked to measurement precision, which is often compromised by sensor misalignment errors. To mitigate these errors, this study proposes a practical calibration method using a standard magnetic source, achieving effective misalignment correction with minimal system alteration. The proposed method is validated through both simulations and localization experiments. Simulation results indicate that the root mean square error (RMSE) of the calibrated tensor values is reduced by three orders of magnitude compared to the uncalibrated state. Experimental results further demonstrate that the average localization error decreases from 0.040 m to 0.019 m after calibration, corresponding to a 52.5% improvement in positioning accuracy. These results highlight the potential of improving the accuracy of MGTMS-based target localization in practical applications.

MATEC Web of ConferencesVol. 413
North University of China (CN), Brunel University of London (GB)
Openalex Percentile: Top 72%
Geophysics and Gravity Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.