GAS CHROMATOGRAPHIC DETERMINATION OF ETHANOL IN SOFT DRINKS USING VAPOR-PHASE DROP MICROEXTRACTION

A simple express procedure for gas chromatographic determination of ethanol in soft drinks is proposed (kwas, grape juice, non-alcoholic beer), based on headspace microextraction of the analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of the needle of a standard microsyringe for gas chromatography. The detection limit of ethanol is (3–6) × 10 vol. %, the parallel determination time, including headspace extraction, does not exceed 5 min. Propanol-2, which is not detected in beverages, is used as an internal standard. The correctness of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7 % at an ethanol concentration in the sample of 10 vol. %.

Authors

Publication Details

Journal
Журнал аналитической химии / Journal of Analytical Chemistry
Published
2025-01-01
DOI
https://doi.org/10.7868/s3034512x25080043
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GAS CHROMATOGRAPHIC DETERMINATION OF ETHANOL IN SOFT DRINKS USING VAPOR-PHASE DROP MICROEXTRACTION

О. В. Родинков
Журнал аналитической химии / Journal of Analytical Chemistry
Analytical Chemistry and Chromatography
article

GAS CHROMATOGRAPHIC DETERMINATION OF ETHANOL IN SOFT DRINKS USING VAPOR-PHASE DROP MICROEXTRACTION

О. В. Родинков
article en

Abstract

A simple express procedure for gas chromatographic determination of ethanol in soft drinks is proposed (kwas, grape juice, non-alcoholic beer), based on headspace microextraction of the analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of the needle of a standard microsyringe for gas chromatography. The detection limit of ethanol is (3–6) × 10 vol. %, the parallel determination time, including headspace extraction, does not exceed 5 min. Propanol-2, which is not detected in beverages, is used as an internal standard. The correctness of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7 % at an ethanol concentration in the sample of 10 vol. %.

Журнал аналитической химии / Journal of Analytical ChemistryVol. 80(8)
Openalex Percentile: Top 75%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.