Preliminary estimation of the radiobiological response to carbon ion irradiation in silico and in vivo

This study addresses the radiobiological efficacy of carbon ion irradiation generated at the U-70 accelerator facility. Particular emphasis is placed on a comprehensive methodology that integrates computational (in silico) techniques based on the earlier developed software with in vivo experiments on laboratory animals with engrafted tumors. This dual approach refines the spatial-energy parameters of the ion beam, ensures accurate formation of the Bragg peak, and evaluates the contribution of secondary particles to the overall radiobiological impact. The aim of this study was to perform a comprehensive assessment of the relative biological effectiveness of the ion beam. The assessment was carried out using experimentally measured absorbed doses and direct observations of tumor growth dynamics following irradiation, in combination with specially developed mathematical and software tools for validating and predicting the radiation spectrum and linear energy transfer characteristics. The absorbed dose estimate during experimental studies performed using ionization chambers, placed inside the object positioning system. After the irradiation, which take place on the 12 days after the tumor implantation, during the follow up period the tumor growth dynamics was analyzed during 25 days. The findings revealed a high level of radiobiological response to carbon ion irradiation, primarily attributable to the increased linear energy transfer and extensive cluster damage to DNA. The experiments also underscored the necessity for stringent dosimetric control and careful consideration of individual biological variability when assessing therapeutic outcomes. Hence, the integration of modeling and in vivo experimentation provides deeper insights into the mechanisms by which heavy ions interact with biological systems, enhances predictive accuracy for treatment efficacy, and establishes a foundation for optimizing ion therapy protocols in oncology.

Authors

Publication Details

Journal
Radiation and Risk Bulletin of the National Radiation and Epidemiological Registry
Published
2025-01-01
DOI
https://doi.org/10.21870/0131-3878-2025-34-3-131-145
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary estimation of the radiobiological response to carbon ion irradiation in silico and in vivo

А. А. Лычагин, Aleksei Solovev, T.V. Kolesnikova, Н. Г. Минаева et al.
Radiation and Risk Bulletin of the National Radiation and Epidemiological Registry
Radiation Therapy and Dosimetry
article

Preliminary estimation of the radiobiological response to carbon ion irradiation in silico and in vivo

А. А. Лычагин, Aleksei Solovev, T.V. Kolesnikova, Н. Г. Минаева, V. A. Pikalov, M. V. Troshinа, Ya.V. Kizilova, S. N. Кoryakin, T.S. Khozyasheva
article en

Abstract

This study addresses the radiobiological efficacy of carbon ion irradiation generated at the U-70 accelerator facility. Particular emphasis is placed on a comprehensive methodology that integrates computational (in silico) techniques based on the earlier developed software with in vivo experiments on laboratory animals with engrafted tumors. This dual approach refines the spatial-energy parameters of the ion beam, ensures accurate formation of the Bragg peak, and evaluates the contribution of secondary particles to the overall radiobiological impact. The aim of this study was to perform a comprehensive assessment of the relative biological effectiveness of the ion beam. The assessment was carried out using experimentally measured absorbed doses and direct observations of tumor growth dynamics following irradiation, in combination with specially developed mathematical and software tools for validating and predicting the radiation spectrum and linear energy transfer characteristics. The absorbed dose estimate during experimental studies performed using ionization chambers, placed inside the object positioning system. After the irradiation, which take place on the 12 days after the tumor implantation, during the follow up period the tumor growth dynamics was analyzed during 25 days. The findings revealed a high level of radiobiological response to carbon ion irradiation, primarily attributable to the increased linear energy transfer and extensive cluster damage to DNA. The experiments also underscored the necessity for stringent dosimetric control and careful consideration of individual biological variability when assessing therapeutic outcomes. Hence, the integration of modeling and in vivo experimentation provides deeper insights into the mechanisms by which heavy ions interact with biological systems, enhances predictive accuracy for treatment efficacy, and establishes a foundation for optimizing ion therapy protocols in oncology.

Radiation and Risk Bulletin of the National Radiation and Epidemiological RegistryVol. 34(3)
Openalex Percentile: Top 61%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.