Registration of gamma radiation from the 133Ba and 134Cs decay by detectors of the Pripjat system

Three NaI(Tl) detectors of 10 cm x 15 cm, in pairs and the three-detector system, were used to acquire spectra of 133Ba and 134Cs, and to consider registration of gamma radiation from de-excitation of their daughters (133Cs and 134Ba, respectively). The sources were measured for 7200 seconds real time (detector pairs) and 10 000 seconds real time (three-detector system) in the non-coincident mode of counting, as well as in the modes of double and triple gamma coincidences. Based on the photopeak detection efficiencies, minimum detectable activity and ratios of counting rates in the source and background spectra for individual detectors, the non-coincident mode is found to be optimal for 133Ba detection via the 356 keV gamma peak, whereas the mode of double coincidences is found to be optimal for 134Cs detection via the 605 keV and 796 keV gamma peaks.

Authors

Institutions

Publication Details

Journal
Nuclear Technology and Radiation Protection
Published
2025-01-01
DOI
https://doi.org/10.2298/ntrp2502127a
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Registration of gamma radiation from the 133Ba and 134Cs decay by detectors of the Pripjat system

Nevenka M. Antović, Nikolija Lalovic
Nuclear Technology and Radiation Protection
Radioactive Decay and Measurement Techniques
article

Registration of gamma radiation from the 133Ba and 134Cs decay by detectors of the Pripjat system

Nevenka M. Antović, Nikolija Lalovic
article en

Abstract

Three NaI(Tl) detectors of 10 cm x 15 cm, in pairs and the three-detector system, were used to acquire spectra of 133Ba and 134Cs, and to consider registration of gamma radiation from de-excitation of their daughters (133Cs and 134Ba, respectively). The sources were measured for 7200 seconds real time (detector pairs) and 10 000 seconds real time (three-detector system) in the non-coincident mode of counting, as well as in the modes of double and triple gamma coincidences. Based on the photopeak detection efficiencies, minimum detectable activity and ratios of counting rates in the source and background spectra for individual detectors, the non-coincident mode is found to be optimal for 133Ba detection via the 356 keV gamma peak, whereas the mode of double coincidences is found to be optimal for 134Cs detection via the 605 keV and 796 keV gamma peaks.

Nuclear Technology and Radiation ProtectionVol. 40(2)
University of Montenegro (ME)
Openalex Percentile: Top 63%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.