Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds

Abstract Tracking foot motion is critically beneficial for a wide range of applications, from immersive entertainment through to gamified rehabilitation. This study investigated the accuracy of the HTC VIVE Ultimate Tracker against the Vicon motion capture system during human walking. Ten healthy participants (aged 24–44 years) walked on a treadmill at four speeds (0.5 m/s, 1.0 m/s, 1.5 m/s, and 2.0 m/s) while tracking both feet and the pelvis. Agreement between the two systems was evaluated using a linear mixed model, Bland–Altman plots, and concordance correlation coefficients (CCC). Absolute errors ranged from millimetre- to centimetre-level. Linear mixed model (speed × tracker location × movement direction) indicated that absolute errors increased with gait speed. Foot trackers exhibited larger errors than the sacrum location, with greater errors in the medio-lateral and anterior–posterior directions compared to the vertical direction ( p < 0.001). Bland–Altman analyses revealed widening limits of agreement at different speeds (e.g., left foot, anterior–posterior direction: − 20.09 to 20.20 mm at 0.5 m/s, − 29.97 to 27.80 mm at 2.0 m/s). Ultimate Trackers demonstrated almost perfect agreement (CCC: > 0.99) for sacrum tracking and substantial agreement for foot tracking (CCC: > 0.98). These findings highlight the Ultimate Trackers’ potential as cost-effective alternatives for the analysis of human movement, demonstrating research- and clinical-grade performance for sacrum and foot tracking during normal gait speeds (≤ 1.5 m/s). However, the finding that accuracy declined at the 2.0 m/s speed, particularly for foot trajectories and in the anterior–posterior direction, indicates the need for technical refinements for higher-speed movements.

Authors

Institutions

Publication Details

Journal
Virtual Reality
Published
2026-11-16
DOI
https://doi.org/10.1007/s10055-026-01541-w
Citations
3
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
3.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds

Stephen R. Lord, Juno Kim, Yoshiro Okubo, Matthew A D Brodie et al.
3 citations
Virtual Reality
Lower Extremity Biomechanics and Pathologies
3.50
article

Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds

Stephen R. Lord, Juno Kim, Yoshiro Okubo, Matthew A D Brodie, Yixuan He, Peter Humburg
article en
3 citations

Abstract

Abstract Tracking foot motion is critically beneficial for a wide range of applications, from immersive entertainment through to gamified rehabilitation. This study investigated the accuracy of the HTC VIVE Ultimate Tracker against the Vicon motion capture system during human walking. Ten healthy participants (aged 24–44 years) walked on a treadmill at four speeds (0.5 m/s, 1.0 m/s, 1.5 m/s, and 2.0 m/s) while tracking both feet and the pelvis. Agreement between the two systems was evaluated using a linear mixed model, Bland–Altman plots, and concordance correlation coefficients (CCC). Absolute errors ranged from millimetre- to centimetre-level. Linear mixed model (speed × tracker location × movement direction) indicated that absolute errors increased with gait speed. Foot trackers exhibited larger errors than the sacrum location, with greater errors in the medio-lateral and anterior–posterior directions compared to the vertical direction ( p < 0.001). Bland–Altman analyses revealed widening limits of agreement at different speeds (e.g., left foot, anterior–posterior direction: − 20.09 to 20.20 mm at 0.5 m/s, − 29.97 to 27.80 mm at 2.0 m/s). Ultimate Trackers demonstrated almost perfect agreement (CCC: > 0.99) for sacrum tracking and substantial agreement for foot tracking (CCC: > 0.98). These findings highlight the Ultimate Trackers’ potential as cost-effective alternatives for the analysis of human movement, demonstrating research- and clinical-grade performance for sacrum and foot tracking during normal gait speeds (≤ 1.5 m/s). However, the finding that accuracy declined at the 2.0 m/s speed, particularly for foot trajectories and in the anterior–posterior direction, indicates the need for technical refinements for higher-speed movements.

Virtual Reality
UNSW Sydney (AU), Neuroscience Research Australia (AU)
University of New South Wales
Good health and well-being
Openalex Percentile: Top 10%
Lower Extremity Biomechanics and Pathologies
3.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon