Feasibility Study of Frequency-Based Intraocular Pressure Sensing Using Microfabricated Cantilevers

Glaucoma is among the leading causes of blindness worldwide, requiring more sensitive and effective methods for early diagnosis and monitoring. However, current intraocular pressure (IOP) measurement techniques are limited to in-clinic diagnostics and do not provide continuous analysis. The present study proposes and assesses a microfabricated microcantilever device with a piezoelectric material deposited on its surface, with the objective of analyzing its sensitivity within a typical IOP range between 12 and 32 mmHg. The methodology encompassed numerical simulations based on multiphysics modeling using COMSOL Multiphysics software, complemented by a simplified equivalent electrical model to thoroughly investigate the dynamic and electrical behavior of the microcantilever. The results indicated that, despite the relatively low sensitivity achieved within the investigated range, the research provided a deeper insight into the fundamental operational mechanisms of the proposed structure. Furthermore, the study highlighted the limitations of the equivalent electrical model, leading to promising future alternatives for the design and refinement of the microfabricated IOP sensors.

Authors

Institutions

Publication Details

Published
2025-08-25
DOI
https://doi.org/10.1109/inscit66472.2025.11181040
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility Study of Frequency-Based Intraocular Pressure Sensing Using Microfabricated Cantilevers

José Milton Neves de Souza Júnior, Ana Luiza Resende de Castro, Pablo Nunes Agra Belmonte, Leonardo Pires et al.
Mechanical and Optical Resonators
article

Feasibility Study of Frequency-Based Intraocular Pressure Sensing Using Microfabricated Cantilevers

José Milton Neves de Souza Júnior, Ana Luiza Resende de Castro, Pablo Nunes Agra Belmonte, Leonardo Pires, Davies William de Lima Monteiro, João Marcelo Lyra
article en

Abstract

Glaucoma is among the leading causes of blindness worldwide, requiring more sensitive and effective methods for early diagnosis and monitoring. However, current intraocular pressure (IOP) measurement techniques are limited to in-clinic diagnostics and do not provide continuous analysis. The present study proposes and assesses a microfabricated microcantilever device with a piezoelectric material deposited on its surface, with the objective of analyzing its sensitivity within a typical IOP range between 12 and 32 mmHg. The methodology encompassed numerical simulations based on multiphysics modeling using COMSOL Multiphysics software, complemented by a simplified equivalent electrical model to thoroughly investigate the dynamic and electrical behavior of the microcantilever. The results indicated that, despite the relatively low sensitivity achieved within the investigated range, the research provided a deeper insight into the fundamental operational mechanisms of the proposed structure. Furthermore, the study highlighted the limitations of the equivalent electrical model, leading to promising future alternatives for the design and refinement of the microfabricated IOP sensors.

Universidade Federal de Minas Gerais (BR), Logos Technologies (United States) (US)
Openalex Percentile: Top 78%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.