Analog Front-End for ECG Signal Acquisition with Automatic Gain Control

The electrocardiogram (ECG) requires accurate signal acquisition, achieved via an analog front-end (AFE) that amplifies and filters cardiac electrical signals. For compact, lowpower wearable devices, AFE design must balance gain, noise, and power consumption. This paper presents the design of an instrumentation amplifier for ECG signals using three two-stage Miller OTA amplifiers in 28 nm technology, achieving high gain and CMRR over 100 dB. It also includes a driven right leg amplifier, a low-pass filter (250 Hz cutoff) and a programmable gain amplifier (PGA) with gain ranging from $112.5 \mathrm{~V} / \mathrm{V}$ to $450 \mathrm{~V} / \mathrm{V}$. The proposed AFE successfully achieves a high common-mode rejection ratio (CMRR) of 104 dB and moderate power consumption of $14.427 \mu \mathrm{~W}$, meeting the key requirements for ECG signal acquisition in wearable biomedical devices. These results demonstrate the effectiveness of the design strategy, which combines Miller OTA-based instrumentation amplifiers, low-pass filtering, and programmable gain stages. This work highlights the feasibility of implementing low-power, high-gain analog front-end circuits in advanced CMOS technologies for compact, energy-efficient ECG monitoring systems.

Authors

Institutions

Publication Details

Published
2025-08-25
DOI
https://doi.org/10.1109/inscit66472.2025.11181022
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analog Front-End for ECG Signal Acquisition with Automatic Gain Control

V. Guimarães, Paulo César C. de Aguirre, Alessandro Girardi, Crı́stian Müller et al.
ECG Monitoring and Analysis
article

Analog Front-End for ECG Signal Acquisition with Automatic Gain Control

V. Guimarães, Paulo César C. de Aguirre, Alessandro Girardi, Crı́stian Müller, Felipe Z. Righi
article en

Abstract

The electrocardiogram (ECG) requires accurate signal acquisition, achieved via an analog front-end (AFE) that amplifies and filters cardiac electrical signals. For compact, lowpower wearable devices, AFE design must balance gain, noise, and power consumption. This paper presents the design of an instrumentation amplifier for ECG signals using three two-stage Miller OTA amplifiers in 28 nm technology, achieving high gain and CMRR over 100 dB. It also includes a driven right leg amplifier, a low-pass filter (250 Hz cutoff) and a programmable gain amplifier (PGA) with gain ranging from $112.5 \mathrm{~V} / \mathrm{V}$ to $450 \mathrm{~V} / \mathrm{V}$. The proposed AFE successfully achieves a high common-mode rejection ratio (CMRR) of 104 dB and moderate power consumption of $14.427 \mu \mathrm{~W}$, meeting the key requirements for ECG signal acquisition in wearable biomedical devices. These results demonstrate the effectiveness of the design strategy, which combines Miller OTA-based instrumentation amplifiers, low-pass filtering, and programmable gain stages. This work highlights the feasibility of implementing low-power, high-gain analog front-end circuits in advanced CMOS technologies for compact, energy-efficient ECG monitoring systems.

Universidade Federal do Pampa (BR)
Openalex Percentile: Top 59%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.