Exploring Bite Force Measurement using FlexiForce Sensor and Instrumentation Amplifier

Bite force measurement plays a crucial role in applications such as dentistry, biomechanics, and product design, where accurate force quantification is essential. This study investigates a bite force measurement system using FlexiForce sensors in conjunction with a Wheatstone bridge configuration and an Instrumentation amplifier for signal conditioning. The system undergoes five trials for forces ranging from 5 kg to 25 kg, during which the sensor output voltage varies from 0.86 V to 2.51 V. Experimental results confirm a direct proportionality between applied force and sensor output voltage, thereby validating system reliability. Comparative analysis shows that the instrumentation amplifier circuit provides better signal amplification and is more immune to noise than the standard recommended circuit. Additionally, tests under different supply voltages of 5 V and 9 V reveal that the output voltage scales proportionally with the supply voltage. These findings validate the system's effectiveness in bite force measurement, with potential applications in healthcare, robotics, and industrial automation.

Authors

Institutions

Publication Details

Published
2025-08-08
DOI
https://doi.org/10.1109/icbmesh66209.2025.11182235
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Bite Force Measurement using FlexiForce Sensor and Instrumentation Amplifier

Roopa B. Hegde, T.N. Rao, U. Jayachandra Shenoy, Vinayaka M. J et al.
Advanced MEMS and NEMS Technologies
article

Exploring Bite Force Measurement using FlexiForce Sensor and Instrumentation Amplifier

Roopa B. Hegde, T.N. Rao, U. Jayachandra Shenoy, Vinayaka M. J, S Surakshitha
article en

Abstract

Bite force measurement plays a crucial role in applications such as dentistry, biomechanics, and product design, where accurate force quantification is essential. This study investigates a bite force measurement system using FlexiForce sensors in conjunction with a Wheatstone bridge configuration and an Instrumentation amplifier for signal conditioning. The system undergoes five trials for forces ranging from 5 kg to 25 kg, during which the sensor output voltage varies from 0.86 V to 2.51 V. Experimental results confirm a direct proportionality between applied force and sensor output voltage, thereby validating system reliability. Comparative analysis shows that the instrumentation amplifier circuit provides better signal amplification and is more immune to noise than the standard recommended circuit. Additionally, tests under different supply voltages of 5 V and 9 V reveal that the output voltage scales proportionally with the supply voltage. These findings validate the system's effectiveness in bite force measurement, with potential applications in healthcare, robotics, and industrial automation.

Nitte University (IN)
Openalex Percentile: Top 73%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploring Bite Force Measurement using FlexiForce Sensor and Instrumentation Amplifier — Roopa B. Hegde, T.N. Rao, et al. · (2025) | TGRS Research Map | TGRS