A novel hand-eye calibration method for eliminating cumulative error of robot kinematics

Aiming at the problem of hand-eye calibration error caused by the cumulative error of 6-DOF robotic arm motion, a hand-eye calibration method based on external vision is proposed. The method firstly establishes the transformation relationship between the internal vision system and the internal calibration plate through a new hand-eye calibration model, and then uses the external vision system to establish the transformation relationship between the coordinate system of the robot end flange and the coordinate system of the internal calibration plate. Finally, using the above calibration results as the initial value, the iterative optimization method is used to further optimize the hand-eye calibration matrix to obtain accurate hand-eye calibration results. Since the calibration process does not require the relative pose of the robot flange, the influence of the accumulated error of the robot joint arm motion on the hand-eye calibration result is eliminated. Compared with the traditional hand-eye calibration method, the results show that this method can significantly reduce the hand-eye calibration error and has higher stability.

Authors

Institutions

Publication Details

Published
2025-07-11
DOI
https://doi.org/10.1109/cisat66811.2025.11181872
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel hand-eye calibration method for eliminating cumulative error of robot kinematics

Qi Dou, Yupeng Li, Hongbing Li, Junyi Lin
Robotic Mechanisms and Dynamics
article

A novel hand-eye calibration method for eliminating cumulative error of robot kinematics

Qi Dou, Yupeng Li, Hongbing Li, Junyi Lin
article en

Abstract

Aiming at the problem of hand-eye calibration error caused by the cumulative error of 6-DOF robotic arm motion, a hand-eye calibration method based on external vision is proposed. The method firstly establishes the transformation relationship between the internal vision system and the internal calibration plate through a new hand-eye calibration model, and then uses the external vision system to establish the transformation relationship between the coordinate system of the robot end flange and the coordinate system of the internal calibration plate. Finally, using the above calibration results as the initial value, the iterative optimization method is used to further optimize the hand-eye calibration matrix to obtain accurate hand-eye calibration results. Since the calibration process does not require the relative pose of the robot flange, the influence of the accumulated error of the robot joint arm motion on the hand-eye calibration result is eliminated. Compared with the traditional hand-eye calibration method, the results show that this method can significantly reduce the hand-eye calibration error and has higher stability.

Huaqiao University (CN)
Openalex Percentile: Top 66%
Robotic Mechanisms and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.