Multifactorial Analysis of MRI Gradient Safety for Active Implantable Medical Devices: Coil Design, Implant Trajectories, and Scan Configurations

<i>Objective.</i>Electromagnetic (EM) modeling is an effective method for evaluating the gradient safety of magnetic resonance imaging (MRI) for patients with active implantable medical devices (AIMDs). However, the combined effects of multiple factors-including gradient coil design constraints, implanted lead path, gradient strength, and scan configuration-on gradient-induced voltage (GIV) risk has not been systematically investigated. In particular, the magnetic field distribution outside the region of linearity (ROL) of gradient coils cannot be uniquely determined from their nominal gradient profile, and its impact on AIMD gradient safety assessment remains poorly understood.<i>Approach.</i>This study presents a multifactorial analysis of MRI gradient safety by integrating gradient coil modeling with anatomical lead path tracing using a reference human body shell. We examine how variations in coil design constraints affect magnetic field distributions and how these, in turn, influence GIV for three representative AIMDs' pathways: deep brain stimulators (DBSs), cardiac pacemakers (PMs), and sacral nerve stimulators (SNMs). Multiple gradient strengths, coil excitation modes, and scanning positions are assessed.<i>Results.</i>Magnetic field distributions vary significantly between coil designs, particularly in the concomitant<i>B<sub>x</sub></i>and<i>B<sub>y</sub></i>components, with differences reaching up to 53%. These variations result in GIV difference that increases with gradient strength. The maximum GIV differences for DBS, SNM, and PM reach 1.08 V, 0.52 V, and 0.93 V, respectively, under<i>Y</i>-axis excitation. The concomitant field plays a significant role in these differences. Simultaneous excitation of all axes does not always produce the highest GIV due to cancellation effects. Cross-AIMD analysis shows high-risk zones are concentrated in and around the ROL.<i>Significance.</i>This work fills a gap by systematically evaluating how coil design, implant characteristics, gradient strength, and scan configurations influence GIV risk, providing a foundation for more comprehensive, individualized MRI gradient safety assessments.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-09-29
DOI
https://doi.org/10.1088/1361-6560/ae0d28
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multifactorial Analysis of MRI Gradient Safety for Active Implantable Medical Devices: Coil Design, Implant Trajectories, and Scan Configurations

Wanxuan Sang, Luming Li, Changqing Jiang, Peishan Li et al.
Physics in Medicine and Biology
Advanced MRI Techniques and Applications
article

Multifactorial Analysis of MRI Gradient Safety for Active Implantable Medical Devices: Coil Design, Implant Trajectories, and Scan Configurations

Wanxuan Sang, Luming Li, Changqing Jiang, Peishan Li, Xu Boya
article en

Abstract

<i>Objective.</i>Electromagnetic (EM) modeling is an effective method for evaluating the gradient safety of magnetic resonance imaging (MRI) for patients with active implantable medical devices (AIMDs). However, the combined effects of multiple factors-including gradient coil design constraints, implanted lead path, gradient strength, and scan configuration-on gradient-induced voltage (GIV) risk has not been systematically investigated. In particular, the magnetic field distribution outside the region of linearity (ROL) of gradient coils cannot be uniquely determined from their nominal gradient profile, and its impact on AIMD gradient safety assessment remains poorly understood.<i>Approach.</i>This study presents a multifactorial analysis of MRI gradient safety by integrating gradient coil modeling with anatomical lead path tracing using a reference human body shell. We examine how variations in coil design constraints affect magnetic field distributions and how these, in turn, influence GIV for three representative AIMDs' pathways: deep brain stimulators (DBSs), cardiac pacemakers (PMs), and sacral nerve stimulators (SNMs). Multiple gradient strengths, coil excitation modes, and scanning positions are assessed.<i>Results.</i>Magnetic field distributions vary significantly between coil designs, particularly in the concomitant<i>B<sub>x</sub></i>and<i>B<sub>y</sub></i>components, with differences reaching up to 53%. These variations result in GIV difference that increases with gradient strength. The maximum GIV differences for DBS, SNM, and PM reach 1.08 V, 0.52 V, and 0.93 V, respectively, under<i>Y</i>-axis excitation. The concomitant field plays a significant role in these differences. Simultaneous excitation of all axes does not always produce the highest GIV due to cancellation effects. Cross-AIMD analysis shows high-risk zones are concentrated in and around the ROL.<i>Significance.</i>This work fills a gap by systematically evaluating how coil design, implant characteristics, gradient strength, and scan configurations influence GIV risk, providing a foundation for more comprehensive, individualized MRI gradient safety assessments.

Physics in Medicine and BiologyVol. 70(20)
McGovern Institute for Brain Research (US), Chinese Institute for Brain Research (CN), Tsinghua University (CN)
Openalex Percentile: Top 60%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.