Simultaneous Determination of Vancomycin and Creatinine by Dried Plasma Spot Sampling via LC‐MS/MS

Routine monitoring of vancomycin drug concentrations is crucial for optimizing dosages to ensure therapeutic efficacy and minimize adverse effects. Vancomycin's clearance is highly correlated with creatinine clearance. However, in developing countries, the majority of hospitals lack the on-site capacity to measure vancomycin concentrations. Dried plasma spots have emerged as an innovative alternative for biological sample collection. Dried plasma spots facilitate the convenient and rapid acquisition of plasma samples, which are highly suitable for both storage and transportation, and can be dispatched to vancomycin testing laboratories. This study presents a validated methodology for the simultaneous quantification of vancomycin and creatinine in dried plasma spots through liquid chromatography-tandem mass spectrometry. Vancomycin demonstrated excellent linearity within the range 3-50 µg/mL, while creatinine exhibited linearity from 1 to 70 µg/mL (both with r<sup>2</sup> > 0.995). The trueness of all compounds was maintained within ± 15%, the precision was less than 15%, and the recoveries were within acceptable boundaries. Moreover, no significant matrix effects were detected. By employing the Passing-Bablok and Bland-Altman methods, we compared the differences and consistencies between the wet plasma concentrations and dried plasma spot concentrations of vancomycin and creatinine in 71 samples. The results revealed no significant distinctions between the two approaches and showcased comparable consistencies, implying that the dried plasma spots technique can be effectively utilized for the simultaneous determination of vancomycin and creatinine in plasma.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-09-29
DOI
https://doi.org/10.1002/jssc.70279
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Determination of Vancomycin and Creatinine by Dried Plasma Spot Sampling via LC‐MS/MS

Zhihui Sun, Jing Huang, Zhengchao Ji, Chang Sun et al.
Journal of Separation Science
Biosensors and Analytical Detection
article

Simultaneous Determination of Vancomycin and Creatinine by Dried Plasma Spot Sampling via LC‐MS/MS

Zhihui Sun, Jing Huang, Zhengchao Ji, Chang Sun, Haiwei Cao, Yingying Feng, Yijia Qin, Yanyan Li, Wei Xia
article en

Abstract

Routine monitoring of vancomycin drug concentrations is crucial for optimizing dosages to ensure therapeutic efficacy and minimize adverse effects. Vancomycin's clearance is highly correlated with creatinine clearance. However, in developing countries, the majority of hospitals lack the on-site capacity to measure vancomycin concentrations. Dried plasma spots have emerged as an innovative alternative for biological sample collection. Dried plasma spots facilitate the convenient and rapid acquisition of plasma samples, which are highly suitable for both storage and transportation, and can be dispatched to vancomycin testing laboratories. This study presents a validated methodology for the simultaneous quantification of vancomycin and creatinine in dried plasma spots through liquid chromatography-tandem mass spectrometry. Vancomycin demonstrated excellent linearity within the range 3-50 µg/mL, while creatinine exhibited linearity from 1 to 70 µg/mL (both with r<sup>2</sup> > 0.995). The trueness of all compounds was maintained within ± 15%, the precision was less than 15%, and the recoveries were within acceptable boundaries. Moreover, no significant matrix effects were detected. By employing the Passing-Bablok and Bland-Altman methods, we compared the differences and consistencies between the wet plasma concentrations and dried plasma spot concentrations of vancomycin and creatinine in 71 samples. The results revealed no significant distinctions between the two approaches and showcased comparable consistencies, implying that the dried plasma spots technique can be effectively utilized for the simultaneous determination of vancomycin and creatinine in plasma.

Journal of Separation ScienceVol. 48(10)
Beihua University (CN), Jilin University (CN), First Hospital of Jilin University (CN)
Openalex Percentile: Top 74%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.