The use of electrical resistivity measurement as a non-destructive test in precast concrete sleepers’ production

In the production of concrete sleepers, it is common to verify that the concrete has the necessary strength for prestress forces release by testing cylinders cured at equivalent conditions. Considering that electrical resistivity measurements may assess the pore structure evolution of concrete, this study proposes the use of this technique to estimate concrete strength evolution at factory conditions. The use of non-destructive testing methods considerably simplifies and modernizes the industrial process, leading to a reduction in labor time and waste. This paper presents a testing protocol aimed at obtaining correlation graphs between concrete compressive strength and electrical conductivity. As the temperature, size and shape of samples may be variable, this paper also presents an innovative procedure to assess correction factors. This procedure is suitable when the liquid water content is high enough not to influence the resistivity measurement. The proposed method was validated at a factory, showing a high correlation.

Authors

Institutions

Publication Details

Journal
Materiales de Construcción
Published
2025-09-23
DOI
https://doi.org/10.3989/mc.2025.391824
Primary Topic
Geophysical Methods and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The use of electrical resistivity measurement as a non-destructive test in precast concrete sleepers’ production

Ángel Castillo, Melina Clara Scasserra, Luis Fernández Luco
Materiales de Construcción
Geophysical Methods and Applications
article

The use of electrical resistivity measurement as a non-destructive test in precast concrete sleepers’ production

Ángel Castillo, Melina Clara Scasserra, Luis Fernández Luco
article en

Abstract

In the production of concrete sleepers, it is common to verify that the concrete has the necessary strength for prestress forces release by testing cylinders cured at equivalent conditions. Considering that electrical resistivity measurements may assess the pore structure evolution of concrete, this study proposes the use of this technique to estimate concrete strength evolution at factory conditions. The use of non-destructive testing methods considerably simplifies and modernizes the industrial process, leading to a reduction in labor time and waste. This paper presents a testing protocol aimed at obtaining correlation graphs between concrete compressive strength and electrical conductivity. As the temperature, size and shape of samples may be variable, this paper also presents an innovative procedure to assess correction factors. This procedure is suitable when the liquid water content is high enough not to influence the resistivity measurement. The proposed method was validated at a factory, showing a high correlation.

Materiales de ConstrucciónVol. 75(358)
Universidad de Buenos Aires (AR), Instituto de Ciencias de La Construcción Eduardo Torroja (ES)
Universidad de Buenos Aires
Openalex Percentile: Top 66%
Geophysical Methods and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.