Dosimetric study on the effect of minimum distance between optimization structures and planning target volume on small intestine dose in cervical cancer VMAT plans

Cervical cancer radiotherapy often faces challenges in managing gastrointestinal toxicities, particularly due to the dose received by the small intestine. This study investigates the impact of optimization structure margins (1.2-2.4 cm) on reducing small intestine dose and improving plan quality in patients with mean small intestine doses (Dmean_INT) exceeding 25 Gy. A total of 27 cervical cancer patients treated with volumetric modulated arc therapy were retrospectively analyzed. Iterative constraint adjustments were applied to optimization structures at varying distances from the planning target volume (PTV). Five optimization margins (0.6, 1.2, 1.8, 2.4, and 3.0 cm) were created by volumetrically excluding small intestine regions proximal to PTV, with iterative dose constraints. Each plan was named RrIi, where r represents the cutting distance of the optimization structure and i represents the iteration number (ranging from 4-8). Results demonstrated that all optimized plans achieved significant reductions in Dmean_INT compared to the original plans (ORI group), with reductions ranging from 1.21 to 1.83 Gy (P < .001). The R_1.2I_5.5 protocol achieved the most favorable balance, reducing Dmean_INT by 1.23 Gy, corresponding to a 15% to 22% relative risk reduction for Grade ≥ 2 enteritis. Smaller margins (1.2 cm) effectively reduced intermediate-high-dose regions (e.g., V40Gy), while larger margins (2.4 cm) better controlled low-dose regions (e.g., V15Gy), supporting tailored clinical decision-making based on patient characteristics. In conclusion, optimization structure margins of 1.2 to 2.4 cm provide a clinically meaningful framework for reducing small intestine dose while preserving PTV coverage, advancing cervical cancer radiotherapy planning.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-09-26
DOI
https://doi.org/10.1097/md.0000000000044715
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric study on the effect of minimum distance between optimization structures and planning target volume on small intestine dose in cervical cancer VMAT plans

Jinlong Hao, Ban R, Jing Zeng
Medicine
Advanced Radiotherapy Techniques
article

Dosimetric study on the effect of minimum distance between optimization structures and planning target volume on small intestine dose in cervical cancer VMAT plans

Jinlong Hao, Ban R, Jing Zeng
article en

Abstract

Cervical cancer radiotherapy often faces challenges in managing gastrointestinal toxicities, particularly due to the dose received by the small intestine. This study investigates the impact of optimization structure margins (1.2-2.4 cm) on reducing small intestine dose and improving plan quality in patients with mean small intestine doses (Dmean_INT) exceeding 25 Gy. A total of 27 cervical cancer patients treated with volumetric modulated arc therapy were retrospectively analyzed. Iterative constraint adjustments were applied to optimization structures at varying distances from the planning target volume (PTV). Five optimization margins (0.6, 1.2, 1.8, 2.4, and 3.0 cm) were created by volumetrically excluding small intestine regions proximal to PTV, with iterative dose constraints. Each plan was named RrIi, where r represents the cutting distance of the optimization structure and i represents the iteration number (ranging from 4-8). Results demonstrated that all optimized plans achieved significant reductions in Dmean_INT compared to the original plans (ORI group), with reductions ranging from 1.21 to 1.83 Gy (P < .001). The R_1.2I_5.5 protocol achieved the most favorable balance, reducing Dmean_INT by 1.23 Gy, corresponding to a 15% to 22% relative risk reduction for Grade ≥ 2 enteritis. Smaller margins (1.2 cm) effectively reduced intermediate-high-dose regions (e.g., V40Gy), while larger margins (2.4 cm) better controlled low-dose regions (e.g., V15Gy), supporting tailored clinical decision-making based on patient characteristics. In conclusion, optimization structure margins of 1.2 to 2.4 cm provide a clinically meaningful framework for reducing small intestine dose while preserving PTV coverage, advancing cervical cancer radiotherapy planning.

MedicineVol. 104(39)
Tianjin Central Hospital of Gynecology Obstetrics (CN)
Openalex Percentile: Top 64%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.