Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol

Continuous monitoring (CM) solutions can facilitate faster detection and repair of emissions compared to traditional survey methods. This study tested 13 CM solutions over 12 weeks using single-blind controlled testing. Controlled release rates ranged from 0.08 to 6.75 kg CH4 h−1 and lasted 18 min to 8 h. Six solutions demonstrated 90% method detection limits (DL90s) ranging from 0.5 [0.3, 0.6] kg CH4 h−1 to 6.7 [5.9, 8.0] kg CH4 h−1. Of the 6 solutions, 5 had low False Positive (FP) rates (7.8%–18.9%), and 4 had low False Negative (FN) rates (8.0%–34.1%). Similar to Ilonze et al., the results show that the tested solutions balance method sensitivity with low FP and FN rates. All scanning/imaging solutions achieved high localization precision and accuracy (≥40%) at the equipment unit level. Single quantification estimates exhibited high relative quantification errors, ranging from 33 [0.9, 66]%, 95% confidence interval (CI) to 1326 [1003, 1648]%, 95% CI for small emissions (between 0.1 and 1 kg CH4 h−1) and from 3 [−20, 26]%, 95% CI to 3578 [−2832, 9988]%, 95% CI for large emissions (>1 kg CH4 h−1). The mean detection time for all solutions ranged from 5 h to 5 days. Relative to previous studies, errors in quantification estimates decreased, as did FN and FP rates, with improved DL90s for 2 of the 4 retested solutions. However, the mean detection times increased for 2 solutions, remained constant for one solution, and decreased for 1 of the 4 retested solutions. These findings highlight that continuous, rigorous testing enhances solution performance, with notable improvements observed across multiple testing programs using the same test protocol.

Authors

Institutions

Publication Details

Journal
Elementa Science of the Anthropocene
Published
2025-01-01
DOI
https://doi.org/10.1525/elementa.2025.00020
Citations
1
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
1.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol

Ethan Emerson, Daniel Zimmerle, Fancy Cheptonui, Ryan Brouwer et al.
1 citations
Elementa Science of the Anthropocene
Atmospheric and Environmental Gas Dynamics
1.11
article

Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol

Ethan Emerson, Daniel Zimmerle, Fancy Cheptonui, Ryan Brouwer, Rachel Day, Chiemezie Ilonze, Daniel F. Fleischmann, Ezra J. T. Levin
article en
1 citations

Abstract

Continuous monitoring (CM) solutions can facilitate faster detection and repair of emissions compared to traditional survey methods. This study tested 13 CM solutions over 12 weeks using single-blind controlled testing. Controlled release rates ranged from 0.08 to 6.75 kg CH4 h−1 and lasted 18 min to 8 h. Six solutions demonstrated 90% method detection limits (DL90s) ranging from 0.5 [0.3, 0.6] kg CH4 h−1 to 6.7 [5.9, 8.0] kg CH4 h−1. Of the 6 solutions, 5 had low False Positive (FP) rates (7.8%–18.9%), and 4 had low False Negative (FN) rates (8.0%–34.1%). Similar to Ilonze et al., the results show that the tested solutions balance method sensitivity with low FP and FN rates. All scanning/imaging solutions achieved high localization precision and accuracy (≥40%) at the equipment unit level. Single quantification estimates exhibited high relative quantification errors, ranging from 33 [0.9, 66]%, 95% confidence interval (CI) to 1326 [1003, 1648]%, 95% CI for small emissions (between 0.1 and 1 kg CH4 h−1) and from 3 [−20, 26]%, 95% CI to 3578 [−2832, 9988]%, 95% CI for large emissions (>1 kg CH4 h−1). The mean detection time for all solutions ranged from 5 h to 5 days. Relative to previous studies, errors in quantification estimates decreased, as did FN and FP rates, with improved DL90s for 2 of the 4 retested solutions. However, the mean detection times increased for 2 solutions, remained constant for one solution, and decreased for 1 of the 4 retested solutions. These findings highlight that continuous, rigorous testing enhances solution performance, with notable improvements observed across multiple testing programs using the same test protocol.

Elementa Science of the AnthropoceneVol. 13(1)
Colorado State University (US)
Openalex Percentile: Top 19%
Atmospheric and Environmental Gas Dynamics
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.